Industrial Equipment Experts Since 1980 | Mon–Fri, 7 AM–6 PM ET
No bots. Real experts. 866-333-0728
Get a Fast Quote
Get a Fast Quote

CustomMHS Buyer's Guide

Cabinets & Modular Drawer Storage

Modular drawer cabinets, storage cabinets, safety cabinets and cylinder storage. How to read gauge and capacity specs, what OSHA requires, and where the density claims hold up.

Covers: Rousseau · Strong Hold · Hallowell · Jamco Questions: 866-333-0728 Written and reviewed by: Tom McGovern, owner of CustomMHS · November 2026
Section One

What a cabinet replaces

This is one category where the purchase is usually justified by floor space and labor, not by the cabinet itself.

Quick answers
  • Modular drawer cabinets are for small, valuable, frequently used items. Rousseau R-Series drawers carry up to 400 lb each and L-Series drawers 100 lb each.
  • Steel gauge runs backwards: a lower number is thicker steel. Check the body, the shelves and the hinges separately.
  • A flammable liquid cabinet is defined by OSHA 1910.106(d)(3): double walled with a 1-1/2 inch air space, a three-point lock and a door sill raised at least 2 inches.
  • Oxygen cylinders in storage must be 20 feet from fuel gas and combustibles, or behind a noncombustible barrier at least 5 feet high with a half-hour fire rating.

Nobody buys a storage cabinet because they want a cabinet. They buy one to replace something that is not working: open shelving where things get lost, a bench covered in tooling, or a chemical drum sitting where it should not be. The value is measured against what it replaces:

One

Floor space

A modular drawer cabinet can hold what several shelving units hold. Where square footage is tight, recovered floor is the biggest line in the justification.

Two

Search time

Time spent looking for tooling and parts never shows on a report. Compartments, labels and full drawer access are the fix.

Three

Loss

Tooling and consumables walk. A lock is the cheapest inventory control there is.

Four

Compliance

Flammables and compressed gas carry specific OSHA requirements. Here the cabinet is the control that makes the storage lawful.

Those four justify very different products, so decide which one you are buying against before you compare models.

Please read this part

This guide is educational and reflects the opinion and general experience of CustomMHS as an equipment distributor. It is not a compliance assessment or legal advice. Flammable liquid and compressed gas storage are regulated, so confirm requirements with your authority having jurisdiction, your fire code and your insurer. Product figures are the manufacturers' published figures and can change.

Section Two

Modular drawers: the density argument, honestly

The claims in this category are large. Some hold up and some are marketing.

Short answer: Drawers store more than shelving because each drawer is sized to its contents and you can reach the whole drawer. Work out your own gain in inches instead of trusting a percentage.

What gets claimed

You will see two figures repeated: that modular drawer cabinets save around 70 percent of the floor space of shelving, and that one cabinet replaces about five shelving units. Treat both as manufacturer claims, not measurements. Use them to start a conversation, not as line items in a capital request.

What is true, and why

  • Vertical air. A shelf is set at a fixed spacing. A 12 in shelf opening holding 4 in tall parts wastes 8 in of height on every shelf.
  • Unreachable depth. On a 24 in deep shelf the back several inches are hard to use. A drawer pulls out, so the back is as usable as the front.
  • No compartments. Parts on a shelf need bins, and bins have walls and gaps. Drawer partitions divide the space directly.
Worked example: count the inches
  • The cabinet: 36 in wide, 24 in deep, 60 in high, with fourteen drawers: six at 3 in, six at 4 in and two at 6 in.
  • Drawer height: (6 × 3) + (6 × 4) + (2 × 6) = 54 in of storage height in a 60 in cabinet.
  • Shelving with the same parts: at a 12 in shelf spacing, 3 in tall parts use 3 in and waste 9 in on every shelf.
  • Your number: add up the drawer heights you need, and compare that to the shelf height your parts really use.
Where modular drawers are the wrong answer

They cost more per cubic foot than shelving, and they are not for everything. Bulky items, anything over the drawer rating, low-value consumables and stock that moves in cases belong on shelving or racking. Modular drawers earn their cost on small, valuable, numerous, frequently used items: tooling, inserts, fittings, electronic components and spares.

Section Three

Reading a drawer cabinet spec

A few numbers matter, and one of them is often misread.

Short answer: Start with capacity per drawer. Rousseau R-Series is 400 lb per drawer and L-Series is 100 lb per drawer. Then check width, depth, height and how far the drawer extends.

Capacity per drawer splits the market

The Rousseau R-Series carries up to 400 lb per drawer. The Rousseau L-Series carries 100 lb per drawer. That is a four-to-one difference, and it follows what you store.

A drawer of steel tooling, dies or fittings gets heavy fast. A drawer of electronic components, fasteners or hand tools rarely reaches 100 lb. Weigh a full drawer load instead of estimating.

Total capacity is a ceiling, not a loading plan

Some listings give a total: drawer capacity times the number of drawers. Fourteen drawers at 400 lb is 5,600 lb. That assumes every drawer fully and evenly loaded on a sound floor. Use it to compare cabinets, not to plan how you load one.

Extension and access

Full extension is what makes the back of the drawer usable. It is the difference between a drawer and a deep shelf. The L-Series is listed with full-access drawer extension, and the R-Series with precision-engineered drawer slides.

Footprint

R-Series cabinets come in 24, 30, 36, 48, 54 and 60 in widths. The L-Series is 18 in wide, 21 in or 27 in deep, and 24, 28, 34 or 40 in high, for work cells and positions where a full cabinet is more than the job needs.

Matching the series to the contents
If you are storing Look at Per drawer
Dies, tooling, inserts, dense metal parts Rousseau R-Series Up to 400 lb
Hand tools, small parts, light tooling, documents Rousseau L-Series 100 lb
CNC tooling Rousseau NCM cabinets with polycarbonate or solid doors See listing
Tooling that must travel to the machine Modular drawer cart Up to 400 lb
Specify the inside, not just the box

Liners and foam are what turn a drawer into organized storage. Rousseau offers PVC and foam drawer liners and foam tool protection. With cut foam, a missing tool is visible at once. Order these with the cabinet. For a model-by-model look, see our Rousseau R-Series guide.

Section Four

Configuring the cabinet you order

A modular drawer cabinet is not picked off a shelf. It is a configuration.

Short answer: Decide in this order: duty (400 lb or 100 lb drawers), width and one or two columns, height, then the mix of drawer heights.

One: duty

Choose the 400 lb R-Series for tooling, dies, fixtures and anything heavy. Choose the 100 lb L-Series for light tooling, small parts and general storage in a slim footprint. If the contents are hand tools and the spot is under a bench, the heavy cabinet is capacity you will never load.

Two: width, and one column or two

In 48, 54 and 60 in widths, the R-Series comes two ways. A single column cabinet has drawers that span the full width, which suits long items and large fixtures. A multi-drawer cabinet splits the same footprint into two columns, so you can set different drawer heights on each side and keep two jobs or two machines apart.

In our experience two columns is the better default at these widths. A 60 in wide drawer is heavy to open and invites people to fill it with unrelated items.

Three: height

Height is where the density comes from, and it is set by where the cabinet lives: under a bench, at counter height as a work surface, or full height against a wall. The Rousseau counter height work center is made for the case where the cabinet top is also the work surface.

Four: the drawer mix

This is the decision people rush. A cabinet of identical drawers wastes height on everything shorter than the tallest item, which is the same waste that makes shelving inefficient.

Measure first, then order
  1. Group the items that will share a drawer.
  2. Measure the tallest item in each group and add a little clearance.
  3. Set each drawer height from that measurement.
  4. Put the heaviest drawers at the bottom.
  5. Then choose liners or foam for each drawer.

Depth

A 27 in deep drawer has 12-1/2 percent more area than a 24 in deep drawer of the same width, because 27 divided by 24 is 1.125. Deeper is not always better: a deeper drawer sticks out further into the aisle when open. Check the open drawer against your aisle before you choose.

Section Five

Reading an enclosed cabinet spec

Gauge, shelf capacity, hinges and lock separate a cabinet that lasts from one that sags.

Short answer: Ask for the steel gauge of the body, the shelves and the hinges separately, ask for capacity per shelf, and look for a three-point lock.

Gauge: lower is thicker

Steel gauge is the headline durability number and it runs backwards: 12 gauge is thicker than 18 gauge. Gauge also varies within one cabinet. The body, the shelves and the hinges can be three different gauges, and the cabinet is only as good as the thinnest one that matters for your load.

All-welded versus knocked down

An all-welded body is stiffer and does not loosen over years of slamming doors. Knocked-down cabinets ship flat and cost less to freight, but the assembled cabinet relies on fasteners. For heavy industrial use, all-welded is the specification. For supplies and PPE, knocked-down is often the sensible economy. See all-welded and knocked-down storage cabinets.

Shelf capacity and total capacity

Two numbers again. Capacity per shelf tells you what one level carries. Total capacity tells you what the cabinet carries. Check that the shelves adjust and in what increment, so you can remove the wasted vertical space described in section two.

Hinges and locks

Hinges are where light cabinets fail, because the hinge carries the whole door every time it opens. Count the hinges per door and ask the gauge. A three-point lock secures the door at the top, bottom and center instead of at the handle alone. A padlock hasp lets you use your own locks and your lockout procedures.

Enclosed cabinet questions to ask
Spec What to ask Why it matters
Body Gauge, and all-welded or knocked down Stiffness over years of use
Shelves Gauge and capacity per shelf Whether shelves sag under a concentrated load
Total capacity Published total for the cabinet What the whole cabinet carries
Shelf adjustment Increment in inches Removing wasted vertical space
Hinges Number per door and gauge The most common failure point
Lock Three-point, padlock hasp, keying Security and door stiffness
Section Six

Cabinet types by contents

Once gauge and capacity are settled, the type follows from what goes inside.

Short answer: Solid doors for security, visual doors when people need to see in, ventilated for damp gear, bin and divider cabinets for small parts, and stainless for washdown.

Standard

Storage cabinets

Solid doors, adjustable shelves, lockable. The default for tools, parts and equipment.

Small and large together

Storage cabinets with drawers

Shelves plus drawers, for a mix of large items and small parts.

Visibility

Visual cabinets

See-through doors let people identify contents without opening the cabinet.

Airflow

Ventilated cabinets

For damp areas and gear that goes away wet.

Mixed contents

Combination cabinets

Several kinds of storage in one unit, for a maintenance shop where one cabinet does three jobs.

Small parts

Cabinets with bins and divider cabinets

Bins or dividers behind lockable doors. The Strong Hold divider cabinet we list has 99 openings.

Personnel

Wardrobe cabinets

For PPE, uniforms and personal gear. For more, see lockers.

Clean areas

Stainless steel cabinets

For corrosion resistance and washdown.

Emergency

Emergency response cabinet

Hallowell cabinet that keeps emergency gear together.

Equipment

Computer cabinets

Stationary and mobile cabinets that protect a workstation on the shop floor.

Docks

Shipping and receiving desk

A standing desk with storage for the dock.

Machine shop

Rousseau CNC cabinets

NCM-Series tool storage with polycarbonate or solid doors.

Section Seven

Flammable liquid safety cabinets

Not a heavy-duty cabinet with a warning sticker. The construction is written into the regulation.

Short answer: OSHA 1910.106(d)(3) limits one cabinet to 60 gallons of Category 1, 2 or 3 flammable liquids or 120 gallons of Category 4, and spells out how a metal cabinet must be built.

OSHA 29 CFR 1910.106(d)(3) sets out what a flammable liquid storage cabinet must be. The requirements are specific, which makes them easy to check and easy to be cited for.

OSHA 1910.106(d)(3) requirements for metal cabinets
Item Requirement
Quantity Not more than 60 gallons of Category 1, 2 or 3 flammable liquids, nor more than 120 gallons of Category 4, in one cabinet
Sheet steel Bottom, top, door and sides at least No. 18 gage
Walls Double walled with a 1-1/2 inch air space
Joints Riveted, welded, or made tight by some equally effective means
Door A three-point lock
Door sill Raised at least 2 inches above the bottom of the cabinet
Label "Flammable - Keep Fire Away" in conspicuous lettering

The raised sill is there so the cabinet holds a spill instead of letting it run out under the door. See the Jamco flammable safety storage cabinets we list.

Read this before you buy or repurpose

A standard industrial storage cabinet, however heavy its gauge, is not a flammable storage cabinet. Do not repurpose a general-purpose cabinet for flammables, and do not assume a cabinet complies because it is yellow. This section summarizes the federal OSHA text. Your local fire code, your insurer and NFPA 30 may add or tighten requirements on quantities, the number of cabinets in an area, venting and location. Confirm with your authority having jurisdiction before you settle a layout.

Section Eight

Compressed gas cylinder storage

Cylinder cages solve a specific problem, and the separation numbers are exact.

Short answer: A cage restrains and secures cylinders. Separation is a layout decision: 20 feet between stored oxygen and fuel gas or combustibles, or a rated barrier at least 5 feet high.

Compressed gas cylinders are heavy and unstable standing up, they are pressure vessels, and some gases are dangerous stored together. Cylinder cages handle restraint and security. Separation is handled by layout.

OSHA 1910.253(b)(4): the separation rule

Oxygen cylinders in storage must be separated from fuel-gas cylinders or combustible materials, especially oil or grease, by at least 20 feet, or by a noncombustible barrier at least 5 feet high with a fire-resistance rating of at least one-half hour.

That gives two paths. If you have the floor, take the 20 feet. If you do not, the barrier is the alternative, and it must meet both the height and the fire rating. Note the rule covers combustibles, oil and grease as well as fuel gas. In a shop, that is the half people miss.

  • Ventilation. Cylinder storage needs airflow so a leak disperses. This is why it is a cage and not a sealed cabinet.
  • Restraint. Cylinders must be secured so they cannot fall.
  • Vertical or horizontal. Confirm the right orientation for your gas and cylinder type.
  • Security. Lockable.
  • Size. Cages are sized to a cylinder count and diameter. Measure yours.
The cage is one control among several

Cylinder storage also involves valve caps, separating full from empty, keeping cylinders away from heat, and handling procedures. A cage does not make a storage area compliant by being there.

Section Nine

Security and access control

The lock is often the reason for the purchase.

Short answer: A three-point lock with a padlock hasp and a master keyed plan covers most shops. Save electronic locks for places where you need a record of who opened what.

Three-point locking

Secures the door at the top, bottom and center. It is harder to pry and keeps a tall door from flexing.

Padlock hasp

Lets you use your own padlocks and keying, and lets a cabinet take part in lockout procedures.

Electronic locks

Worth it when you need to know who opened a cabinet and when, or when access changes by shift or role. Plan for batteries before you commit across many cabinets.

Keying plan

Decide before ordering whether cabinets are keyed alike, keyed differently or master keyed. Keyed alike is convenient, and one lost key opens everything. Keyed differently is secure and makes a key management job. Master keyed is usually the right middle ground.

Match the lock to the real threat

Most shop loss is casual: a tool borrowed and not returned, consumables taken because they were sitting out. A basic lock plus visible accountability solves that.

Section Ten

Anchoring, mobility and placement

These are heavy, tall objects. Placement is a safety decision.

Short answer: Follow the manufacturer's anchoring instructions, load heavy drawers low, open one drawer at a time, and leave room in front for a fully open drawer plus a person.

Anchoring and tip-over

A tall cabinet with loaded upper drawers has a high center of gravity, and pulling out a loaded upper drawer moves that weight forward, outside the footprint. Follow the manufacturer's anchoring instructions for your model, and get engineering input in seismic zones or where the slab is questionable.

Two habits reduce the risk in any cabinet: load heavy drawers low, and open one drawer at a time.

Weight on the floor

These units are heavy before you load them, and a drawer cabinet can carry thousands of pounds. A row of loaded cabinets is a large concentrated load. On a mezzanine or an upper floor, confirm the floor rating before you place them.

Mobile cabinets and carts

A modular drawer cart brings tooling to the machine, which removes a walk that happens dozens of times a shift. The trade-offs: casters raise the center of gravity, mobile units are not anchored, and they need a floor good enough to roll on. Lock the casters.

Access clearance

A cabinet needs the depth of a fully open drawer plus a person in front of it, kept clear. Double-door cabinets need swing room. Two cabinets facing each other across an aisle both need that space.

Section Eleven

Choosing by application

Find the row that matches the problem in front of you.

Short answer: Dense tooling goes in 400 lb drawers, light parts in 100 lb drawers, general storage behind welded doors, and flammables and cylinders in cabinets and cages built for them.

Tool room full of shelving with bins on it
Modular drawer cabinets. Run the inch count in section two on your own parts.
Dies, inserts, dense metal tooling
Rousseau R-Series at up to 400 lb per drawer. Weigh a full drawer load.
Hand tools, small parts, light tooling
Rousseau L-Series at 100 lb per drawer.
CNC tooling
Rousseau NCM cabinets. Polycarbonate doors to identify tooling at a glance, solid doors where dust and coolant mist are the bigger problem.
Tooling needed at the machine
A modular drawer cart. Load heavy drawers low and lock the casters.
Heavy parts and equipment behind a lock
An all-welded storage cabinet. Check shelf capacity separately from total, and look at the hinges.
Shared supplies people need to find fast
Visual doors, so contents show without opening.
Maintenance shop with mixed contents
A combination cabinet or a cabinet with drawers.
Damp area, or gear stored wet
A ventilated cabinet.
Food, pharmaceutical or laboratory
Stainless steel.
Flammable liquids
A cabinet meeting OSHA 1910.106(d)(3). Respect the 60 and 120 gallon limits and check local fire code.
Compressed gas cylinders
A ventilated, lockable cage with restraint, plus a layout with 20 feet of separation or a 5 foot barrier rated one-half hour.
PPE, uniforms and personal gear
Wardrobe cabinets or lockers.
Section Twelve

Common and costly mistakes

Each of these is expensive to find after delivery.

Short answer: The common ones are putting the wrong inventory in drawers, reading one capacity number, loading heavy drawers high, and using an ordinary cabinet for flammables.

Putting the wrong inventory in modular drawers

They earn their cost on small, valuable, frequently used items. Filled with bulky low-value stock they are expensive shelving.

Reading only one capacity number

Per drawer or per shelf tells you what one level carries. The total assumes even loading.

Misreading gauge

Lower is thicker, and body, shelves and hinges can each be different.

Sizing drawers by convenience

An oversized drawer brings back the wasted height you left shelving to escape.

Loading heavy drawers high

It raises the center of gravity and puts the worst lift at shoulder height.

Skipping the anchor

Follow the manufacturer's instructions for anchoring tall drawer cabinets.

Repurposing a standard cabinet for flammables

Gauge alone does not make a safety cabinet. The double wall, the raised sill and the three-point lock are the requirement.

Treating a cylinder cage as full compliance

The 20 foot separation, or the rated barrier, is a layout decision the cage does not solve.

Not deciding the keying plan before ordering

Easy to specify up front and a nuisance to change later.

Forgetting drawer clearance in the layout

A cabinet needs a fully open drawer plus a person in front of it.

Section Thirteen

Frequently asked questions

What comes up most often on quote calls.

Do modular drawer cabinets really save 70 percent of the floor space?

That figure, and the claim that one cabinet replaces about five shelving units, are manufacturer claims, not measurements. The reason behind them is real: drawers remove the wasted height of a fixed shelf spacing and let you reach the whole drawer. Add up the drawer heights you need and compare them to the shelf height your parts really use.

What is the difference between a 100 lb and a 400 lb drawer?

It is the main split in modular drawers. The Rousseau R-Series carries up to 400 lb per drawer and suits dies, tooling and dense metal parts. The Rousseau L-Series carries 100 lb per drawer and suits light tooling, small parts and general storage. Weigh a full drawer load instead of estimating.

Is a cabinet's total capacity really usable?

Treat it as a ceiling. Fourteen drawers at 400 lb is 5,600 lb, which assumes every drawer fully and evenly loaded on a sound floor. Spread weight low and evenly and stay inside it.

What steel gauge should I look for?

Lower numbers are thicker. Ask for the gauge of the body, the shelves and the hinges separately, since they can differ within one cabinet. Lighter gauges are fine for supplies and PPE.

All-welded or knocked down?

All-welded is stiffer and does not loosen over years of use, and it is the specification for heavy industrial duty. Knocked-down ships flat and saves freight but relies on fasteners. For supplies and light storage it is often the sensible economy.

What makes a cabinet a flammable storage cabinet?

Construction under OSHA 1910.106(d)(3): bottom, top, door and sides of at least No. 18 gage sheet iron, double walled with a 1-1/2 inch air space, joints riveted, welded or made equally tight, a three-point lock, and a door sill raised at least 2 inches. It must be labeled "Flammable - Keep Fire Away." Local fire code and NFPA 30 may add requirements.

How much flammable liquid can one cabinet hold?

OSHA 1910.106(d)(3) limits one cabinet to not more than 60 gallons of Category 1, 2 or 3 flammable liquids, or not more than 120 gallons of Category 4. Local fire code may also limit how many cabinets you can place in one area.

How far apart do oxygen and fuel gas cylinders have to be?

Under OSHA 1910.253(b)(4), oxygen cylinders in storage must be at least 20 feet from fuel-gas cylinders or combustible materials, especially oil or grease, or separated by a noncombustible barrier at least 5 feet high with a fire-resistance rating of at least one-half hour.

Do I need to anchor cabinets to the floor?

Follow the manufacturer's instructions for your model. Pulling out a loaded upper drawer moves weight forward outside the footprint, which is the tip-over case. Load heavy drawers low and open one drawer at a time.

Can I put these on a mezzanine?

Check the floor rating first. These cabinets are heavy empty and can carry thousands of pounds. Confirm with whoever holds the mezzanine's rated capacity before placing them.

Should cabinets be keyed alike or differently?

Decide before you order. Keyed alike is convenient but one lost key opens every cabinet. Keyed differently is secure and creates a key management job. Master keyed is usually the right middle ground.

Section Fourteen

Quick-reference spec table

Regulatory citations and published figures referenced in this guide. Confirm the exact model before ordering.

Regulatory requirements
Requirement Figure Source
Flammable cabinet, Category 1, 2, 3 limit 60 gallons maximum OSHA 1910.106(d)(3)
Flammable cabinet, Category 4 limit 120 gallons maximum OSHA 1910.106(d)(3)
Flammable cabinet sheet steel At least No. 18 gage OSHA 1910.106(d)(3)
Flammable cabinet wall Double walled, 1-1/2 in air space OSHA 1910.106(d)(3)
Flammable cabinet door Three-point lock OSHA 1910.106(d)(3)
Flammable cabinet sill Raised at least 2 in OSHA 1910.106(d)(3)
Oxygen from fuel gas or combustibles 20 ft, or a 5 ft barrier rated one-half hour OSHA 1910.253(b)(4)
Published product figures
Product Sizes Capacity Notes
Rousseau R-Series modular drawer cabinets Widths 24, 30, 36, 48, 54 and 60 in Up to 400 lb per drawer Single column, or two columns in 48, 54 and 60 in widths. Tops in butcher block, steel with rubber mat, galvanized, stainless and slope top. PVC and foam liners.
Rousseau L-Series compact cabinets 18 in wide. 21 or 27 in deep. 24, 28, 34 or 40 in high 100 lb per drawer Full-access drawer extension. For lighter-duty storage in a slim footprint.
Modular drawer cart See listing Up to 400 lb per drawer Mobile.
Strong Hold divider cabinet See listing See listing 99 openings.
Before you order

OSHA citations reflect the regulation text as published. Local fire code, NFPA 30 and your authority having jurisdiction may add requirements. For gauge, capacity, drawer configuration, keying or anchoring guidance on a specific model, call and we will pull the data sheet.

About the author. Tom McGovern is the owner of CustomMHS, an industrial material handling distributor serving the US, Canada and Mexico. He has worked in material handling since 1981 and has quoted and specified the Rousseau modular drawer cabinets, storage cabinets, flammable safety cabinets and cylinder cages sold at CustomMHS. Questions about this guide: 866-333-0728.

Ready for a quote?

Send us these details and a material handling specialist will reply, typically within one business day.

  • Dimensions
    Size of the load and the space it goes in
  • Load
    Weight per item, shelf or level
  • Quantity
    How many units you need
  • Delivery ZIP code
    For freight pricing
  • Drawing
    A sketch, photo or spec sheet, if you have one
Get a Fast Quote Call 866-333-0728

Tell us what goes inside

Give us the contents, the weights, the floor space you have and whether it needs to lock. We will configure drawer heights and quote it. Quotes are reviewed by material handling specialists, typically within one business day.

866-333-0728

Browse cabinets & modular drawer storage at custommhs.com

No bots. No guesswork. Real experts.

Sources

OSHA 29 CFR 1910.106(d)(3) · OSHA 29 CFR 1910.253(b)(4) · Rousseau, Strong Hold, Hallowell and Jamco figures as published on CustomMHS product listings.

Disclaimer. This guide is educational content and reflects the opinion and general experience of CustomMHS. It is not a compliance assessment or legal advice. Flammable liquid and compressed gas storage are regulated, so confirm requirements with your authority having jurisdiction, your fire code and your insurer. Anchoring and floor loading should be verified for your building. Reviewed November 2026.