Section One
Arm length is the capacity
Every other decision in cantilever racking follows from this one.
Quick answers
- The longer the arm, the less it holds. MECO Series 1000 arms are listed at 1,000 lb at 12 in and 300 lb at 48 in.
- The base length is matched to the arm length, not the height. Longer arms need a longer base.
- Use straight arms for lumber, sheet and flat stock, and inclined arms for pipe, tube and anything that rolls.
- Uprights, arms and brace sets do not interchange between series. Pick the series for the material you will store in five years.
- A run is one starter unit plus add-on units. Cantilever rack has its own standard, ANSI MH16.3.
An arm is supported at one end only. The load hangs out in front of the column, and the further out it hangs, the more it bends the arm and its connection. The MECO listings say it directly: capacity goes down as arm length goes up.
MECO Series 1000 arms, listed capacity by length
| Arm length |
Capacity per arm |
| 12 in |
1,000 lb |
| 18 in |
750 lb |
| 24 in |
600 lb |
| 30 in |
500 lb |
| 36 in |
400 lb |
| 42 in |
350 lb |
| 48 in |
300 lb |
Four times the reach, 70% less capacity. That is why ordering the longest arm that will fit is the most expensive habit in this category. See Series 1000 straight arms.
Match the arm to the depth of the load
Measure the depth of the bundle or stack, front to back, and choose the arm for that depth. Do not add length for margin. Every extra inch of arm costs capacity.
The same trade shows up in height. On the heavier series, taller uprights generally pair with more, shorter arms at a lower capacity per arm, and shorter uprights with fewer, longer arms.
Please read this part
This guide is educational and reflects the opinion and general experience of CustomMHS as an equipment distributor. It is not a structural design. Cantilever rack design, anchoring and seismic requirements must be handled by the manufacturer or a qualified engineer. Capacities are the manufacturer's published figures. Confirm the current data sheet for your exact model before you order.
Section Two
Three capacities, not one
Per arm, per upright and per system. A quote that gives one of them has given a third of the answer.
Short answer: Check the load on each arm against the arm rating, the total on each column against the upright rating, and how the material spans the run.
The three capacities
| Capacity |
What it covers |
| Per arm |
What one arm carries at its listed length |
| Per upright |
The total on one column and base. The column and base have their own limit, so it is not simply arms times arm rating |
| Per system |
What the run holds, given how the material spans the uprights |
Worked example: load per arm
If that bundle is 36 in deep, a 36 in Series 1000 arm at 400 lb is not enough. You need more arms under the bundle or a heavier series.
What the heavier series buys
At 36 in arms, the Series 1000 units are listed at 400 lb per arm and the Series 4000 units at 1,200 lb. Same reach, three times the load, because the column, base and connection are all heavier. Compare quotes at the same arm length.
Listed starter units, capacity per arm
| Model |
Series |
Type |
Height and base |
Arms |
Per arm |
| SM6 |
1000 |
Single starter |
6 ft by 33 in |
6 arms, 12 in |
1,000 lb |
| SM8 |
1000 |
Single starter |
8 ft by 33 in |
8 arms, 24 in |
600 lb |
| SMD10 |
1000 |
Double starter |
10 ft by 78 in |
24 arms, 36 in |
400 lb |
| SU8 |
4000 |
Single starter |
8 ft by 37 in |
8 arms, 24 in |
2,000 lb |
| SU10 |
4000 |
Single starter |
10 ft by 49 in |
12 arms, 36 in |
1,200 lb |
| SU12 |
4000 |
Single starter |
12 ft by 61 in |
16 arms, 48 in |
1,000 lb |
| SDU10 |
4000 |
Double starter |
10 ft by 82 in |
24 arms, 36 in |
1,200 lb |
See Series 1000 starter and add-on units and Series 4000 starter and add-on units.
Section Three
The base is set by the arm
Not by the height, which is what most people assume.
Short answer: A longer arm needs a longer base to resist tipping forward. Check the base against the arm on every quote.
A cantilever upright is a lever. Load on the arm tries to tip the column forward, and the base reaching out in front is what resists it. So the base grows with the arm.
MECO Series 2000 uprights: base length and the arms it takes
| Base length |
Arms it takes |
| 38 in |
12 in, 18 in and 24 in |
| 50 in |
30 in and 36 in |
| 62 in |
42 in and 48 in |
The 6 ft upright and the 20 ft upright come in the same three base lengths. Height changes the column. Arm length changes the base. See Series 2000 single sided uprights.
The base is floor space
A 62 in base is 5 ft 2 in of floor in front of the column. Double sided bases are listed at 78 in and 82 in, which is 6 ft 6 in and 6 ft 10 in. Add the aisle your truck needs on each loaded face before you settle the layout.
A ten-second check
If a quote shows 48 in arms on a 38 in base, something is wrong. Cross-check the base against the arm.
Section Four
Straight or inclined arms
Same capacity, different jobs.
Short answer: Straight arms for material that stays put. Inclined arms for material that rolls. Add a lip only where the load can shift.
Stable material
Straight arms
For lumber, sheet goods, flat bar and structural shapes. Easy to load and unload, and no wasted height. See Series 1000, Series 2000 and Series 4000 straight arms.
Anything that rolls
Inclined arms
The arm tilts the load back toward the column so pipe, round tube, conduit and round bar cannot roll forward. See Series 1000, Series 2000 and Series 4000 inclined arms.
On the listings, straight and inclined arms of the same length carry the same rated capacity. This is a containment decision, not a strength decision.
Worked example: a straight arm is not level when empty
Straight arms are built with a pitch of at least 3/8 in per foot, so they come level when loaded.
Rise at the tip of an empty arm
| Arm length |
Math |
Rise at the tip |
| 24 in (2 ft) |
2 × 3/8 in |
3/4 in |
| 36 in (3 ft) |
3 × 3/8 in |
1-1/8 in |
| 48 in (4 ft) |
4 × 3/8 in |
1-1/2 in |
An empty rack whose arms point slightly up is built correctly.
Retaining lips
Both arm types are offered with and without a lip. A lip holds material that may shift. It is also something a fork or a bundle has to clear on every load and unload. Use lips where material shifts, and leave them off where the incline already holds it.
Arm adjustment
Arms move up and down the column on 3 in centers with a hairpin keeper and no tools. Plan to adjust the levels once after the real material arrives.
Section Five
Single sided or double sided
The question is where the rack stands.
Short answer: Single sided goes against a wall. Double sided stands in the open with an aisle on each face.
Against a wall
Single sided
Arms on one face, with the base reaching forward. Listed bases run from 33 in to 62 in depending on arm length. See Series 1000, Series 2000 and Series 4000 single sided uprights.
Open floor
Double sided
Arms on both faces of one column, with the base reaching both ways. You buy one column, one base and one set of braces for two faces. See Series 1000, Series 2000 and Series 4000 double sided uprights.
Double sided needs an aisle on both faces
That is the whole catch. Against a wall, half of a double sided rack cannot be reached. Measure the aisles before you count the storage.
Section Six
Series, and why they do not mix
The most expensive mistake in this category, and it is stated on the listing.
Short answer: Series 1000, 2000 and 4000 parts do not interchange. The series you choose is a long-term decision.
Nothing crosses between series
The Series 1000 listing states that its uprights, arms and brace sets are not interchangeable with any other rack series, and the Series 2000 listing says the same. A bay of one series cannot be extended with parts of another.
What each series is for
| Series |
Duty |
Listed range |
Typical use |
| 1000 |
Medium |
6 ft, 8 ft and 10 ft uprights. Arms from 1,000 lb at 12 in to 300 lb at 48 in |
Lighter material and shorter runs |
| 2000 |
Medium-heavy |
Uprights from 6 ft to 20 ft in 2 ft steps, in three base lengths |
Lumber, steel service and fabrication, where height matters |
| 4000 |
Heavy |
Units listed at 2,000 lb per arm at 24 in and 1,000 lb at 48 in |
Structural steel and heavy pipe |
Brace sets are also by series: Series 1000, Series 2000 and Series 4000. If your material is getting heavier or you expect to add height, stepping up a series now costs far less than running two systems later. Keep a record of which series you installed.
Section Seven
Starter and add-on units
Cantilever is sold as a chain, not as separate bays.
Short answer: The first bay needs two uprights. Each bay after it needs one more. Order one starter and the rest as add-ons.
Material spans between uprights. A starter unit has the uprights, arms and braces for one complete bay. An add-on has one upright with its arms and braces, and uses the last upright of the bay before it.
Starter and add-on, Series 1000 as listed
| Unit |
Type |
Arms included |
| SM6 |
Single starter |
6 arms, 12 in |
| AM6 |
Single add-on |
3 arms, 12 in |
| SMD10 |
Double starter |
24 arms, 36 in |
| AMD10 |
Double add-on |
12 arms, 36 in |
Worked example: a four-bay run
Counting the units
| Step |
Math |
Result |
| Uprights in the run |
4 bays + 1 |
5 uprights |
| Starter |
The first 2 uprights |
1 starter |
| Add-ons |
5 − 2 |
3 add-ons |
| Arms with SM6 and AM6 |
6 + 3 + 3 + 3 |
15 arms, 3 per upright |
Draw the run and count uprights, not bays. A break in the run needs its own starter. You can extend later, but only within the same series.
Section Eight
ANSI MH16.3
Cantilever rack has its own standard, separate from pallet rack.
Short answer: Ask for a design to ANSI MH16.3, which edition, and the capacity per arm and per upright at your arm length in writing.
ANSI MH16.1 covers pallet rack. ANSI MH16.3, Design, Testing and Utilization of Industrial Steel Cantilever Storage Racks, is the standard for this category. The Rack Manufacturers Institute has described a recent revision that:
- adds defined deflection limits for arms,
- has the engineer of record identify what must be inspected before the rack goes into use,
- updates how product, seismic and snow loads are combined, which matters for racks in outdoor yards,
- revises the overturning figures used in anchor design, and
- adds guidance on how load placement along the arm affects arm forces.
Three things to ask for
Confirmation that the design follows ANSI MH16.3 and which edition. The inspection items from the engineer. And a load plaque or capacity document giving per-arm and per-upright capacity for your configuration.
This is orientation so you can ask informed questions. The design has to be done by the manufacturer or a qualified engineer against the full standard and your local requirements.
Section Nine
Anchoring, overturning and the floor
A loaded cantilever rack is trying to tip forward all day.
Short answer: Anchor every upright as the manufacturer specifies, install the full brace set, and find out your slab thickness before the rack is designed.
Single sided racks are the vulnerable case
A double sided rack loaded evenly on both faces largely balances. A single sided rack has all its load on one side and relies on base length and anchors. The wall behind it keeps the rack from going backward. It does nothing to stop it from going forward.
- Slab: an anchor is only as good as the concrete. Thin or cracked slabs and joints under a base reduce what it holds.
- Anchors: the number, diameter and depth come from the manufacturer or engineer.
- Seismic: requirements depend on location and affect base size, anchors and sometimes the layout. Give us the installation address.
- Bracing: brace sets tie the uprights into a rigid run. They are structural, and they are specific to the series.
- Outdoors: raise snow, wind and finish with us for a rack in a yard.
The owner's habits are the same as for pallet rack: inspect on a schedule, take damaged structure out of service, and have capacity re-checked after any change. Our pallet racking guide covers load plaques and inspection.
Section Ten
How the load is placed
Two racks with identical parts can be safe or overloaded depending on where the material sits.
Short answer: Spread long material across as many arms as it reaches, keep it back toward the column, put heavy material low, and give short pieces their own place.
Load placement
| Placement |
What happens |
| Spread across the arms |
A 20 ft length across five uprights shares its weight among them. That is the design intent |
| Short material on one or two arms |
The whole weight lands where the design assumed a share |
| Pushed out to the arm tip |
The same weight bends the arm more. Load toward the column |
Short pieces are the practical hazard
Shops collect short remnants, and they end up on the same rack as full lengths. Give offcuts a marked location, on shorter arms or a lower level. It costs nothing and removes the most likely way this rack gets overloaded.
Put heavy material on the lower arms. It lowers the center of gravity of the run and reduces the tipping force.
Section Eleven
Choosing by material
What we would specify for the loads that come up most.
Short answer: Pick the arm type by whether the material rolls, the arm length by the load depth, and the series by the weight per arm.
Dimensional lumber
Straight arms, no lip, matched to the bundle depth. Series 1000 or 2000 by bundle weight, with enough levels to separate sizes.
Pipe, tube and conduit
Inclined arms. Lips only where bundles are loose. Pipe is dense, so check the load per arm first.
Bar stock and structural steel
Series 4000. Straight arms for flats and shapes, inclined for round bar. Give offcuts a marked place.
Sheet and panels
Straight arms, with enough arms under the sheet to prevent sag.
Mixed lengths in a fabrication shop
Series 2000 for the height range, straight arms, and a level set aside for short pieces.
Against a wall, limited floor
Single sided, the shortest arms the load allows, and height instead of reach.
Open floor, high volume
Double sided, with an aisle on both faces.
Outdoor yard
Tell us it is outdoors so snow, wind and finish are part of the design.
Section Twelve
Common and costly mistakes
Each is easy to avoid at quote time.
Short answer: Do not order long arms for margin, do not mix series, and do not order a starter for every bay.
Ordering the longest arm that fits
Capacity falls from 1,000 lb at 12 in to 300 lb at 48 in on Series 1000.
Assuming the base follows height
It follows arm length.
Working from one capacity figure
Per arm, per upright and per system are different numbers.
Comparing series at different arm lengths
An 8 ft unit with 24 in arms is 600 lb per arm in Series 1000 and 2,000 lb in Series 4000.
Mixing parts between series
Uprights, arms and brace sets do not interchange.
Ordering a starter for every bay
Bays after the first share an upright.
Thinking an upward-pitched empty arm is a defect
Straight arms are pitched 3/8 in per foot.
Treating the wall as structure
Base length and anchors resist tipping, not the wall.
Storing offcuts with full lengths
Short heavy pieces load one or two arms.
Asking for MH16.1
Cantilever rack is ANSI MH16.3.
Section Thirteen
Frequently asked questions
What comes up most often on quote calls.
Why does a longer cantilever arm hold less?
The arm is supported at one end, so a load further from the column bends the arm and its connection more. MECO Series 1000 arms are listed at 1,000 lb at 12 in and 300 lb at 48 in.
How long does the base need to be?
It is matched to the arm length. On MECO Series 2000 uprights, a 38 in base takes 12 in to 24 in arms, a 50 in base takes 30 in and 36 in arms, and a 62 in base takes 42 in and 48 in arms.
Straight arms or inclined arms?
Straight arms for lumber, sheet and other stable material. Inclined arms for pipe, tube, conduit and round bar, because the tilt keeps them from rolling forward. Rated capacity is the same at the same length.
Do I need retaining lips?
Only where material can shift during handling. Lips slow loading and unloading, so leave them off where the incline already holds the load.
Single sided or double sided?
Single sided against a wall. Double sided on open floor with an aisle on both faces.
Can I mix parts between series?
No. MECO states that uprights, arms and brace sets are not interchangeable between series.
What is the difference between a starter and an add-on unit?
A starter is one complete bay with two uprights. An add-on has one upright with its arms and braces and shares the last upright of the bay before it.
Which standard applies to cantilever racking?
ANSI MH16.3. ANSI MH16.1 covers pallet rack.
Does a cantilever rack have to be anchored?
Yes. Anchor it as the manufacturer or engineer specifies. A loaded cantilever rack produces a constant forward tipping force, especially a single sided one.
Does it matter where on the arm I put the load?
Yes. Keep material back toward the column and spread it across as many arms as it reaches. Load at the arm tip bends the arm more for the same weight.
Why do my empty arms point upward?
Straight arms are built with a pitch of at least 3/8 in per foot so they come level under load. A 48 in arm rises about 1-1/2 in at the tip when empty.
Section Fourteen
Quick-reference tables
Listed figures. Confirm against the listing before you order.
Arm capacity by length, MECO Series 1000
| Arm length |
Capacity per arm |
| 12 in |
1,000 lb |
| 18 in |
750 lb |
| 24 in |
600 lb |
| 30 in |
500 lb |
| 36 in |
400 lb |
| 42 in |
350 lb |
| 48 in |
300 lb |
Listed starter and add-on units
| Model |
Series |
Type |
Height and base |
Arms |
Per arm |
| SM6 |
1000 |
Single starter |
6 ft by 33 in |
6 arms, 12 in |
1,000 lb |
| AM6 |
1000 |
Single add-on |
6 ft by 33 in |
3 arms, 12 in |
1,000 lb |
| SM8 |
1000 |
Single starter |
8 ft by 33 in |
8 arms, 24 in |
600 lb |
| SMD10 |
1000 |
Double starter |
10 ft by 78 in |
24 arms, 36 in |
400 lb |
| AMD10 |
1000 |
Double add-on |
10 ft by 78 in |
12 arms, 36 in |
400 lb |
| SU8 |
4000 |
Single starter |
8 ft by 37 in |
8 arms, 24 in |
2,000 lb |
| SU10 |
4000 |
Single starter |
10 ft by 49 in |
12 arms, 36 in |
1,200 lb |
| SU12 |
4000 |
Single starter |
12 ft by 61 in |
16 arms, 48 in |
1,000 lb |
| SDU10 |
4000 |
Double starter |
10 ft by 82 in |
24 arms, 36 in |
1,200 lb |
What we list
| Series |
Listings |
| 1000 |
Units, single uprights, double uprights, brace sets, straight arms, inclined arms |
| 2000 |
Single uprights, double uprights, brace sets, straight arms, inclined arms |
| 4000 |
Units, single uprights, double uprights, brace sets, straight arms, inclined arms |
Before you order
Tell us the material, its length, depth and weight per bundle, how many levels, wall or open floor, indoors or outdoors, and the installation address. Ask for capacity per arm and per upright at your arm length.
About the author. Tom McGovern has worked in the industrial material handling industry since 1981, bringing over 45 years of hands-on experience helping businesses select the right equipment for their applications. His expertise includes specifying and quoting MECO cantilever rack units, uprights, straight arms, inclined arms and brace sets.
Questions about this guide? Call 866-333-0728 to speak with an experienced material handling specialist.