Lockers: Steel, Welded & Wire

Three different products get called a locker: knock-down steel lockers, all-welded industrial lockers, and wire tenant lockers. They are specified with different numbers. This guide covers all three.

Covers: Hallowell · Strong Hold · WireCrafters Questions: 866-333-0728 Written and reviewed by: Tom McGovern · November 2026
Section One

The three kinds of locker

Pick the family first. Everything else follows from it.

Quick answers
  • Three products get called a locker: knock-down steel lockers, all-welded industrial lockers, and wire tenant lockers. Decide which one you need before you choose a size.
  • A standard locker sits on 6 in legs, so a 72 in locker needs 78 in (6 ft 6 in) of clear height, and more with a slope top.
  • OSHA 1910.141(e) requires separate storage for street clothes and protective clothing where that clothing may be contaminated with toxic materials.
  • The 2010 ADA Standards require at least 5 percent of lockers, and no fewer than one of each type, to be accessible, within a reach range of 15 to 48 in above the floor.

Family one

Knock-down steel

The familiar school and workplace locker. Formed sheet steel, shipped flat and assembled on site, or bought factory assembled. Hallowell bodies are typically 24 gauge with 16 gauge doors. Buy it for employee changing, schools, offices and light industrial use.

Family two

All-welded industrial

12 gauge steel, welded, arrives assembled, with three-point locking and a padlock hasp. Weighs hundreds of pounds and costs several times as much. Buy it for tools, abuse and theft-prone areas.

Family three

Wire tenant lockers

Welded wire mesh in a steel frame, 7 ft 6 in tall and sized in feet, not inches. Buy it for resident storage in condos and apartments, multi-tenant buildings and bulk storage.

The quick test

What goes inside, and who is trying to get in? A coat and a lunch bag in a staffed building is a knock-down locker. A tool set in a plant with contractor traffic is all-welded. Bicycles and boxes for tenants is wire. For enclosed cabinets and flammable storage, see the Cabinets and Modular Drawer Storage guide.

Please read this part

This guide is educational and reflects the opinion and general experience of CustomMHS as an equipment distributor. It is not a compliance assessment or legal advice. Accessibility and workplace rules are enforced locally, and state or local codes may be stricter than the federal standards cited here. Confirm requirements with your architect, your authority having jurisdiction and your safety officer. Dimensions, gauges and part numbers are from manufacturer data and our listings and can change, so confirm them on the listing or your quote.

Section Two

Reading a Hallowell model number

A few characters describe the whole locker. Learn them and you can compare any two quotes.

Short answer: The letters are the locker family. The four digits are units wide, width, depth and height. The number after the dash is the tier count.

URB   1   2   2   8   -   1   A
URB
Ready Built family
1
Units wide: 1 is a single locker, 3 is a three-wide bank
2
Width code: 2 is 12 in
2
Depth code: 2 is 12 in
8
Height code: 8 is a 72 in locker on a 78 in frame
-1
Tier count: one opening per column
A
Assembled

So URB1228-1A is a single 12 in wide, 12 in deep, 72 in high, one-tier locker that ships assembled. U3548-2 is a three-wide bank of 15 in wide, 24 in deep, two-tier lockers: six openings of 36 in each.

Position codes on the Hallowell steel locker lines
Position Meaning Values
Letters Family U Premium, URB Ready Built, USV Safety View, UMS MedSafe, USS stainless
Digit 1 Units wide 1 is single, 3 is a three-wide bank
Digit 2 Width 2 is 12 in, 5 is 15 in, 8 is 18 in
Digit 3 Depth 2 is 12 in, 5 is 15 in, 8 is 18 in, 1 is 21 in, 4 is 24 in
Digit 4 Height 6 is a 60 in locker on a 66 in frame. 8 is a 72 in locker on a 78 in frame
After the dash Tiers 1, 2, 3, 4, 5, 6 or 16
Trailing letters Variant G Galvanite, HDV heavy-duty ventilated, A assembled, ASB assembled with slope top and closed base
Where the decoder stops working

Bulk storage lockers state their size outright, so BSL363690 is 36 in by 36 in by 90 in. Emergency response, Max View and cell phone lockers each use their own numbering. Read the listed dimensions on those.

Section Three

Choosing the tier configuration

Tier count is a headcount decision, not a storage decision.

Short answer: Count the people first, then check that the opening holds what they bring. Only a single-tier locker takes a full-length coat.

Tier to opening height
Tiers Opening Holds
1 60 or 72 in Hanging coat or uniform, with a hat shelf above. One person per column.
2 30 or 36 in A folded coat, a bag and boots. Not a hanging uniform.
3 20 or 24 in Bags, boots, helmets and personal effects.
4 18 in Offered on the Safety View box line.
5 and 6 12 in Wallets, phones, keys. Five tiers in a 60 in locker, six in a 72 in locker.
16 person Sixteen compartments in one 72 in wide unit Small items only, for the most people in the least floor space.
Worked example: 20 feet of wall
  • Wall: 20 ft is 240 in.
  • 12 in wide lockers: 240 ÷ 12 = 20 columns. That is 20 people at one tier, 40 at two tiers, 60 at three tiers and 120 at six tiers.
  • 15 in wide lockers: 240 ÷ 15 = 16 columns. That is 16, 32, 48 and 96 people.
  • Then check the opening: if people bring winter coats and the math says three tiers, you need more wall, not a smaller locker.

Wardrobe and box lockers latch differently

Wardrobe lockers (one, two and three tier) use a multi-point latch with a recessed handle. Box lockers (four tiers and up) use a single-point friction catch. The friction catch is simpler, and in a bank that sees hundreds of open-and-close cycles a day it is the part that wears.

Section Four

Width, depth and frame height

Three dimensions, and only one of them is usually chosen well.

Short answer: Use 12 in wide for a coat and a bag, 15 in where people change daily, and 18 in for bulky gear. Measure the ceiling against the frame height, not the locker height.

Width

Widths are 12, 15 and 18 in per opening. Twelve inches is the default. Fifteen inches makes a locker comfortable instead of tolerable. Eighteen inches is for bulky gear, helmets and cold-weather clothing.

Lockers are sold as singles or as three-wide banks. A bank is one factory unit that shares side panels, which costs less per opening and installs faster than three singles. Order banks wherever the run allows.

Depth

Depth by line, from our listings
Line Depths
Premium 12, 15, 18, 21, 24 in
Heavy-Duty Ventilated 12, 15, 18, 21 in
Safety View, Galvanite, Ready Built 12, 15, 18 in
MedSafe and Type 304 stainless 18 in only

Twelve inches suits box lockers and personal effects. Fifteen inches is the general-purpose choice. Deeper is for gear and boots. Anything at the back of a 24 in locker is out of sight.

Frame height and the 6 in legs

Worked example: how tall is it really, in feet and inches
  • 72 in locker on 6 in legs: 78 in, or 6 ft 6 in.
  • 60 in locker on 6 in legs: 66 in, or 5 ft 6 in.
  • Add a slope top: the rise is about 4 in on a 12 in deep locker and about 8 in on a 24 in deep locker.
  • 78 in frame, 24 in deep, slope top: 78 + 8 = 86 in, or 7 ft 2 in to the peak. Check that against the ceiling, ducts and sprinkler heads.

The legs raise the locker so the floor can be cleaned underneath, which matters in food, healthcare and industrial rooms.

Section Five

Door style and ventilation

The door decides airflow, sightlines and how hard the locker is to defeat.

Short answer: Louvered doors suit general use. Choose ventilated doors and sides for wet or sweaty clothing, and see-through doors where contents must be visible.

Standard

Louvered steel

Pressed louvers give modest airflow. The default on Premium, MedSafe and Galvanite lockers. Right for general workplace and school use. See Premium box lockers.

Visibility

Safety View

16 gauge steel doors with clear polycarbonate panels, so contents show without opening. See Safety View lockers and Safety View box lockers.

Airflow

Heavy-Duty Ventilated

Perforated doors and sides move air through the whole body, with 14 gauge doors on a 16 gauge frame and body. See ventilated lockers.

Most visibility

Max View all-welded

Expanded metal sides and perforated doors, so you can see in from four sides. See Hallowell Max View lockers.

Ventilation is a maintenance decision

Damp clothing in a louvered locker is where most locker room odor complaints start. If people put away wet or sweaty clothing, specify the ventilated line when you order. You cannot add airflow later.

Section Six

Knock-down, ready built or all-welded

The biggest driver of installed cost.

Short answer: Compare installed cost, not purchase price. Knock-down saves freight and costs labor. Factory-assembled lockers cost more to ship and nothing to build.

Knock-down
Ships flat and is assembled on site. Lowest freight and purchase price, highest labor. Many Hallowell lines are listed assembled or unassembled.
Ready Built
Factory-assembled lockers in one, two, three and six tiers. They arrive built and include padlocks.
Ready Built II
Factory-assembled lockers with a slope top and closed base already fitted, with padlocks included.
All-welded
Strong Hold, Max View and the emergency response line. Welded at the factory, with no assembly option. They arrive complete and heavy.
Accessories follow the assembly choice

Some Hallowell accessories, including coat rods and flat top fillers, are made for knock-down lockers only. Decide how the lockers will be assembled before you build the accessory list.

Knock-down makes sense for a large run in an easy room where you have labor. Ready Built makes sense for small quantities, awkward access, occupied buildings, and jobs where assembly is billed at contractor rates. Ready Built II makes sense when you were going to add a slope top and closed base anyway.

Section Seven

Locks and access control

Including the one compatibility trap that catches people.

Short answer: Use built-in combination locks for assigned lockers and padlocks for shift lockers. Confirm the door latch type before you order built-in locks.

Most lockers ship without locks. The factory-assembled Ready Built lines, which include padlocks, are the exception. The lock is a separate decision from the locker.

Hallowell lock options, as named in Hallowell accessory data
Part Type Notes
1970 Built-in combination lock Nothing for the user to lose.
1770 Built-in key lock For assigned lockers where management holds the keys.
1925 Combination padlock Hangs on the hasp instead of fitting into the door.
Check this before you order built-in locks

The built-in locks are not recommended for single-point-latch doors. Confirm the latch type on the exact locker you are buying before adding built-in locks to the order. Where they do not suit, use a padlock. See Hallowell locker accessories.

  • Assigned lockers. One person, one locker, long term. Built-in combination locks work well. Keep a master record of combinations.
  • Shift lockers. Different people daily. User-supplied padlocks are simplest.
  • Managed issue. Built-in key locks, with the facility holding the master, where lockers must be opened on demand.
  • Phones and tablets. Hallowell cell phone and tablet lockers come with a padlock provision, a key lock or an electronic keypad. The electronic version costs several times the padlock version.
Decide keying before the purchase order

Keyed alike, keyed differently or master keyed costs nothing to specify at order time and is a nuisance afterward. Say which on the purchase order.

Section Eight

Bases, tops and fillers

The parts that turn a row of lockers into a finished installation.

Short answer: Closed bases cover the gap under the legs, slope tops stop clutter and dust on top, and fillers close the gaps at walls. Order them with the lockers.

Hallowell finishing parts, as named in Hallowell accessory data
Part What it does Part families
Closed base Fills the open space under the 6 in legs. Front bases match the locker width, side bases match the depth. KCFB front, KCSB side
Individual slope top One per locker, sized by width and depth. KISTT, with KISE end closures
Continuous slope top Comes in 72 in lengths for a long unbroken run. CST, with CSE end closures
Front filler Closes the gap between the run and the wall, in 66 in and 78 in heights. KFSF
Flat top filler and corner Closes the tops. Knock-down lockers only. KFTF, FTC
Coat rod Extra on single-tier lockers. Knock-down lockers only. KCR
Worked example: fillers
  • Wall: 20 ft 5 in is 245 in.
  • Run: twenty 12 in lockers is 240 in.
  • Gap: 245 − 240 = 5 in. Order a 6 in front filler in the frame height you are using and trim it to fit.

Fillers are the parts everyone forgets, and they separate an installation that looks built in from one that looks dropped in place. If you specify closed bases for looks, remember you give up cleaning under the lockers.

Section Nine

Matching material to environment

Where standard painted steel will not last, and what replaces it.

Short answer: Use Galvanite for damp and corrosion, ventilated lockers for wet clothing, MedSafe for clinical areas, and stainless only where washdown or a hygiene standard requires it.

Material options and where each belongs
Line Construction Specify it for
Galvanite Galvannealed steel, 24 gauge body and 16 gauge doors Damp and corrosion-prone areas: pool decks, car washes, coastal sites, unheated buildings
MedSafe 16 gauge louvered doors with an antimicrobial powder coat Healthcare, labs and clinical areas
Type 304 stainless Stainless throughout, 18 in deep, one, two or six tier Washdown, food processing, pharmaceutical and cleanroom
Heavy-Duty Ventilated 14 gauge doors, 16 gauge frame and body, perforated Wet or contaminated clothing, where the problem is moisture
Stainless is a last resort, not an upgrade

Type 304 stainless lockers cost several times the equivalent painted locker. Specify them where washdown chemicals or a hygiene standard require it. Where the problem is only dampness, Galvanite solves it for much less.

If you want bases, slope tops and fillers to match the lockers, confirm the accessory color against the locker color before ordering. Do not assume the color names line up.

Section Ten

All-welded industrial lockers

For when a pried door is the real risk.

Short answer: Strong Hold lockers are 12 gauge all-welded steel with three-point locking. Buy them for tools, theft-prone areas and abuse, not for a clean office.

Strong Hold lockers are a different product from formed sheet lockers. They are 12 gauge all-welded steel on welded legs, with three-point locking and a padlock hasp. A knock-down locker body is typically 24 gauge. Lower gauge numbers mean thicker steel, so 12 gauge is far heavier material, and the whole unit is welded, not bolted.

Strong Hold locker families we list
Family What it is
Welded slim line lockers Single-tier lockers with a door and shelf.
Two tier slim line lockers Two openings per column.
Four door lockers Standard two-tier, four-door units.
Four door lockers with drawers Shelves plus drawers for tools.
Mini tier solid door lockers 18 in wide compartments, 12 gauge steel.
Vented door lockers Ventilated doors for gear that goes away damp.
36 compartment locker and personal lockers Many small compartments for personal effects.
Cell phone lockers and wall mounted lockers Small-item storage.

Ask for the shelf capacity on the exact model if the locker will hold tooling instead of clothing. And check the overall height: as with knock-down lockers, a 72 in locker on 6 in legs is 78 in overall, and a slope top adds more.

Hallowell also makes all-welded emergency response lockers for turnout and tactical gear.

Section Eleven

Wire tenant and bulk storage lockers

Sized in feet, not inches, and quoted as a run.

Short answer: Quote a wire locker row as one starter plus add-ons. Each add-on shares a frame with the unit before it, so it costs less than a starter.

WireCrafters tenant lockers give a resident or tenant a lockable space big enough to walk into. They are 7 ft 6 in high, in widths and depths of 3, 4 and 5 ft, in one and two tier versions. The mesh on our listings is 10 gauge wire in a 2 in by 2 in welded pattern, in a 1-1/4 in angle frame.

-S Starter
The first section of a run, with its own framing on both sides.
-A Add-on
Extends a row by sharing framing with the unit before it. Costs less than a starter.
-DS Double starter
A double-tier starter: two compartments stacked in one footprint.
-DA Double add-on
A double-tier add-on.
Worked example: a ten-locker row
  • Units: one starter and nine add-ons, not ten starters.
  • Length: ten lockers 4 ft wide make a run about 40 ft long.
  • Double tier: the same 40 ft serves 20 tenants, with each compartment about half height.

Hallowell bulk storage and TA-50 gear lockers

Hallowell bulk storage lockers are welded wire mesh in steel frames, 90 in (7 ft 6 in) high, in 36 and 48 in widths and 36, 48 and 60 in depths, in one and two tier versions with starters and add-ons. For military and tactical gear, see WireCrafters TA-50 gear lockers.

Section Twelve

OSHA, ADA and layout

Two requirements that change what you order, and the clearances that make a room work.

Short answer: Where protective clothing may be contaminated, OSHA requires separate storage for it. The ADA requires 5 percent of each type of locker to be accessible, reachable between 15 and 48 in above the floor.

OSHA change rooms

29 CFR 1910.141(e)

"Whenever employees are required by a particular standard to wear protective clothing because of the possibility of contamination with toxic materials, change rooms equipped with storage facilities for street clothes and separate storage facilities for the protective clothing shall be provided."

In practice that means two separate storage spaces for each affected employee, which doubles the opening count for that headcount. Confirm which of your standards trigger it before you size the room.

ADA accessible lockers

2010 ADA Standards that affect a locker order
Requirement Standard Section
Quantity Where lockers are provided, at least 5 percent, but no fewer than one of each type, must comply 225.2.1
High reach 48 in maximum above the floor 308.2.1 and 308.3.1
Low reach 15 in minimum above the floor 308.2.1 and 308.3.1
Worked example: how many accessible lockers
  • 120 box lockers: 5 percent is 6.
  • 30 wardrobe lockers: 5 percent is 1.5, so 2.
  • Each type counts separately: that room needs at least 6 accessible box lockers and 2 accessible wardrobe lockers.
  • Reach: in a two-tier 72 in locker on 6 in legs, the lower opening runs from 6 in to 42 in above the floor, and the upper opening starts at 42 in. In practice the accessible lockers are lower-tier openings.

State and local accessibility codes can be stricter than the federal standard. Confirm the count and the heights with your architect or authority having jurisdiction before ordering.

Layout and clearance

  • Aisle width. Allow for an open door plus a person changing in front of it. A 12 in door swings 12 in into the aisle.
  • Benches. Benches use aisle. Plan for the bench, a seated person and room to walk past.
  • Anchoring. Secure tall locker banks to the wall or floor, following the manufacturer's instructions.
  • Cleaning. The 6 in legs are there so floors can be cleaned underneath.
Section Thirteen

Common and costly mistakes

What goes wrong on locker orders.

Short answer: The frequent ones are measuring to the locker height instead of the frame, choosing tiers from wall length alone, and forgetting fillers.

  • Measuring to the locker height instead of the frame height. A 72 in locker needs 78 in on standard legs, and more with a slope top.
  • Choosing tier count from wall length alone. A three-tier locker will not take a winter coat.
  • Ordering built-in locks for single-point-latch doors. Confirm the latch first.
  • Comparing knock-down against assembled on purchase price. Compare installed cost.
  • Ordering knock-down-only accessories for assembled lockers.
  • Forgetting fillers. Measure the wall, subtract the run, and order fillers on the same purchase order.
  • Buying louvered doors for wet clothing. You cannot add ventilation later.
  • Buying depth you cannot reach. Twenty-four inches is for gear.
  • Assuming accessory colors match locker colors. Confirm before ordering.
  • Quoting a wire locker run as all starters. One starter, then add-ons.
  • Missing the OSHA separate-storage requirement.
  • Treating ADA as an afterthought. The 5 percent applies to each type of locker installed.
Section Fourteen

Frequently asked questions

The questions that come up most often on locker quotes.

How do I read a Hallowell locker model number?

The letters give the family. The first digit is units wide (1 or 3), the second is the width (2 is 12 in, 5 is 15 in, 8 is 18 in), the third is the depth (2 is 12, 5 is 15, 8 is 18, 1 is 21, 4 is 24 in), and the fourth is the height (6 is a 60 in locker on a 66 in frame, 8 is a 72 in locker on a 78 in frame). The number after the dash is the tier count.

What is the difference between a wardrobe locker and a box locker?

Tier count and latch. Wardrobe lockers are one, two or three tier and use a multi-point latch with a recessed handle. Box lockers are four tiers and up, with 12 in or 18 in openings, and use a single-point friction catch. Wardrobe lockers take garments. Box lockers take personal effects.

How tall is a locker really?

Taller than the locker height. Standard lockers sit on 6 in legs, so a 72 in locker is 78 in (6 ft 6 in) overall and a 60 in locker is 66 in (5 ft 6 in). A slope top adds about 4 in on a 12 in deep locker and about 8 in on a 24 in deep locker.

Should I buy knock-down or assembled?

Compare installed cost, not purchase price. Knock-down suits large runs in easy rooms where you have labor. Assembled suits small quantities, awkward access and occupied buildings. Some accessories, including coat rods and flat top fillers, are for knock-down lockers only.

Do lockers come with locks?

Usually not. The factory-assembled Hallowell Ready Built lines include padlocks. Otherwise the lock is a separate line item: a built-in combination lock, a built-in key lock or a padlock. Built-in locks are not recommended for single-point-latch doors, so confirm the latch type first.

How many accessible lockers does the ADA require?

Section 225.2.1 of the 2010 ADA Standards requires that where lockers are provided, at least 5 percent, but no fewer than one of each type, be accessible. Section 308 sets the reach range at 48 in maximum and 15 in minimum above the floor. State and local codes can be stricter, so confirm with your architect or authority having jurisdiction.

What does OSHA require for employee lockers?

29 CFR 1910.141(e) requires that where employees must wear protective clothing because of possible contamination with toxic materials, change rooms have storage for street clothes and separate storage for the protective clothing. That means two storage spaces for each affected employee.

Which locker is right for wet or sweaty clothing?

The Hallowell Heavy-Duty Ventilated line, with perforated doors and sides so air moves through the whole body. Standard louvered doors give only modest airflow.

What should I use in a damp or corrosive area?

Galvanite for dampness, unheated buildings and coastal sites. Type 304 stainless for washdown, food, pharmaceutical and cleanroom. Stainless costs several times as much, so use Galvanite where the issue is only moisture.

When is an all-welded locker worth the money?

When a pried door is a real risk or the room sees abuse. Strong Hold lockers are 12 gauge all-welded steel with three-point locking and a padlock hasp, against a typical 24 gauge body on a knock-down locker. For a school or office they are more than you need.

How do I quote a run of wire tenant lockers?

One starter and then add-ons, because each add-on shares framing with the unit before it. A ten-unit row is one starter and nine add-ons. The double versions are double tier: two compartments stacked in the same footprint.

Section Fifteen

Quick-reference tables

Everything above, condensed.

Requirements that change what you order
Requirement Figure Source
Separate storage for street and protective clothing Required where protective clothing may be contaminated with toxic materials OSHA 29 CFR 1910.141(e)
Accessible lockers At least 5 percent, no fewer than one of each type ADA 225.2.1
High reach 48 in maximum ADA 308.2.1 and 308.3.1
Low reach 15 in minimum ADA 308.2.1 and 308.3.1
Locker lines we list
Line Tiers Notes
Hallowell Ready Built 1, 2, 3, 6 Factory assembled, padlocks included
Hallowell Ready Built II 1, 2, 3, 6 Factory assembled with slope top, closed base and padlocks
Hallowell Premium box 5, 6, 16 Assembled or unassembled
Hallowell Safety View and box 1, 2, 3 and 5, 6, 16 See-through doors
Hallowell Heavy-Duty Ventilated 1, 2, 6 Ventilated doors and sides
Hallowell Galvanite 1, 2, 3, 6 Corrosion resistant
Hallowell MedSafe 1, 2 Antimicrobial finish
Hallowell Type 304 stainless 1, 2, 6 Stainless steel
Hallowell cell phone and tablet 5 Padlock, key or electronic
Strong Hold all-welded Varies 12 gauge welded steel, three-point locking
WireCrafters tenant and Hallowell bulk storage 1, 2 Wire mesh, starters and add-ons

Specify-it checklist

1. What goes inside, and who might break in?
Picks the family: knock-down steel, all-welded or wire.
2. How many openings does the shift need?
Sets the tier count against the wall you have.
3. Do people hang garments?
If yes, single tier.
4. Clear height available?
Locker height plus 6 in legs, plus the slope top if fitted.
5. Wet, damp or corrosive?
Ventilated for wet clothing, Galvanite for corrosion, stainless for washdown.
6. Assigned or shift use?
Built-in combination for assigned, padlock for shift. Check the latch.
7. Who assembles it?
Knock-down, assembled or Ready Built. Decide before listing accessories.
8. Wall length minus locker run?
Order fillers for the remainder on the same purchase order.
9. Protective clothing contamination risk?
Separate storage required. Double the openings for that headcount.
10. Accessible count and reach?
5 percent of each type, within 15 to 48 in. Confirm with your authority having jurisdiction.

About the author. Tom McGovern has worked in the industrial material handling industry since 1981, bringing over 45 years of hands-on experience helping businesses select the right equipment for their applications. His expertise includes specifying and quoting Hallowell steel lockers, Strong Hold all-welded lockers and WireCrafters wire tenant lockers.

Questions about this guide? Call 866-333-0728 to speak with an experienced material handling specialist.

Ready for a quote?

Send us these details and a material handling specialist will reply, typically within one business day.

  • Dimensions
    Size of the load and the space it goes in
  • Load
    Weight per item, shelf or level
  • Quantity
    How many units you need
  • Delivery ZIP code
    For freight pricing
  • Drawing
    A sketch, photo or spec sheet, if you have one
Get a Fast Quote Call 866-333-0728

Send us the headcount

Tell us how many people need a locker, what they put in it, the wall length and clear height you have, and whether anything gets stored wet. We will size the run, spec the locks and fillers, and quote the model numbers. Quotes are reviewed by material handling specialists, typically within one business day.

866-333-0728

Browse steel, welded and wire lockers

No bots. No guesswork. Real experts.

Sources

OSHA 29 CFR 1910.141(e) · 2010 ADA Standards for Accessible Design 225.2.1, 308.2.1, 308.3.1 · Hallowell published locker and accessory data · Strong Hold and WireCrafters published product data · CustomMHS product listings.

Disclaimer. This guide is educational content and reflects the opinion and general experience of CustomMHS. It is not a compliance assessment or legal advice. Accessibility and workplace requirements are enforced locally, and state or local codes may be stricter than the federal standards cited. Confirm requirements with your architect, your authority having jurisdiction and your safety officer. Dimensions, configurations and part numbers change, so confirm current details on the product listing or quote before ordering. Reviewed November 2026.