Industrial Equipment Experts Since 1980 | Mon–Fri, 7 AM–6 PM ET
No bots. Real experts. 866-333-0728
Get a Fast Quote
Get a Fast Quote

CustomMHS Buyer's Guide

Pallet Rack Components

Buying racking by the component is where orders go wrong. Beams are rated per pair. Uprights are one per bay after the first, not two. And the deck count depends on the beam length. This guide is the bill of materials.

Covers: Husky roll-formed · MECO structural · decking and accessories Questions: 866-333-0728 Written and reviewed by: Tom McGovern · November 2026
Section One

What this guide adds

A narrow scope on purpose, because the engineering is covered in the guide next door.

Quick answers
  • Uprights = number of bays + 1. A ten-bay row needs eleven upright frames, not twenty.
  • Beams are rated per pair. A three-level bay needs six beams. Check whether the price on the quote is each or per pair.
  • For two pallets side by side, add at least 10 in to the combined pallet width. Two 48 in pallets need a 108 in beam, not a 96 in beam.
  • Decks per level depend on the beam length: one 46 in deck on a 48 in beam, two on a 96 in beam, three on a 144 in beam.
  • Floor anchors and load plaques are not in the box. Plan for both.

Our Pallet Racking and Storage Racks guide covers the engineering: why every capacity has a condition, how beam and frame capacity change, deflection, anchoring, load plaques, inspection and ANSI MH16.1. If you have not settled the rack type, bay size or capacity, start there.

This guide starts once those decisions are made and you are looking at a component list, working out what goes on the purchase order. To browse, see pallet rack components.

Please read this part

This guide is educational and reflects the opinion and general experience of CustomMHS as an equipment distributor. It is not a structural design. Rack capacity depends on the engineered configuration, the floor and the location. Part numbers, sizes and capacities are from the CustomMHS listings. Confirm the current data sheet for your exact model before you order.

Section Two

What a rack run is made of

Eight things, and only three of them are obvious.

Short answer: Frames, beams and decking make the rack. Crossbars, row spacers, wall ties, protection and anchors make it a working installation.

The parts of a rack run
Component What it does Quantity is set by
Upright frames The vertical structure: two columns with bracing Number of bays, plus one
Step beams The horizontal load members, two per level Levels and bays
Decking Supports the load across the beams. Wire, solid or perforated Beam length
Crossbars Extra support between the beams of a level What you store
Row spacers Tie back-to-back rows together and hold the flue space open Frame positions in a back-to-back run
Wall ties Tie a single row to a building wall Frame positions along the wall
Post protectors and end guards Take the fork truck impact instead of the upright Aisle exposure
Floor anchors Fix the base plates to the slab Every column
The flue space is a fire code question

The flue is the gap between back-to-back rows. Fire codes call for it to stay open so sprinkler water reaches the lower levels, which is why row spacers are chosen by the flue space you need. Confirm the dimension with your fire protection engineer or building official. A flue stop keeps pallets from being pushed into that space.

Section Three

Starter and add-on: the quantity math

The most common ordering error in this category.

Short answer: The first bay needs two frames. Every bay after it shares a frame and needs one more.

Upright frames = number of bays + 1
Starter
Two uprights and the beam levels. Begins a row or stands alone.
Add-on
One upright and the beam levels. Shares the last frame of the bay before it.
Beams
Two per level, in every bay

A ten-bay run is one starter and nine add-ons: eleven uprights, not twenty.

Listed pre-configured units, showing the pattern
Unit Uprights Beams Decks
Three-level starter, 48 in beams 2 6 3
Two-level add-on, 96 in beams 1 4 4
Three-level starter, 96 in beams, no decking 2 6 None

Worked example: how long is the run?

Each upright adds 3 in to the run, per the unit listings. For ten bays of 108 in beams:

Run length
Step Math Result
Beams 10 × 108 in 1,080 in
Uprights 11 × 3 in 33 in
Total 1,080 in + 33 in 1,113 in, or 92 ft 9 in

Check that against the wall-to-wall dimension, with working room at the ends, before you order. Pre-configured units and loose components can both build the same run. Units are convenient. Loose components let you set different heights or capacities by level.

Section Four

Reading the part numbers

Each family builds its specification into the part number.

Short answer: On Husky uprights, IU is followed by a column code, depth and height. On step beams, IB is followed by a series letter, profile height and length.

IU 18 420 144
IU
Upright frame
18
Column: 18 is 3 in by 1-5/8 in, 24 is 3 in by 3 in
420
Depth: 42 in
144
Height: 144 in, which is 12 ft
The five schemes
Family Pattern Worked example
Roll-formed uprights IU + column code + depth + height IU24480192 is a 3 in by 3 in column, 48 in deep, 192 in high
Step beams IB + series letter + profile height + length IBX43144 is X series, 4.32 in profile, 144 in long
Wire decking Depth + width + A3 or A4 4846A3 is 48 in by 46 in with three support channels
Structural uprights SF3 or SF4 + depth + height in feet SF4-4824 is 4 in channel, 48 in deep, 24 ft high
Structural beams 2SB + channel depth + length 2SB5-48 is a 5 in channel beam, 48 in long

The beam series letters

Three profile tiers are listed. IBX covers 3.0 in to 4.85 in profiles, IBN is 5.5 in and IBH is 6.0 in. At the same length, a taller profile carries much more. A 144 in IBX43144 is listed at 3,020 lb per pair, and a 144 in IBH60144 at 8,300 lb per pair.

Pre-configured unit codes

Starter and add-on units read like 42x144x48x7383-3SW: 42 in deep, 144 in high, 48 in beams, a beam capacity figure, 3 levels, Starter, Wire decking. An A in place of the S is an add-on, and no W means no decking.

Matching loose beams to existing units

If you are adding loose beams to a run of pre-configured units, have the capacity for the exact beam part number confirmed on the quote.

Section Five

Uprights

Four decisions: depth, height, column size and gauge.

Short answer: Depth and height come from your pallet and building. Column and gauge come from the load. Ask for the frame capacity at your beam spacing in writing.

Husky roll-formed upright options as listed
Specification Listed options
Depths 36 in, 42 in, 48 in
Heights 96 in, 120 in, 144 in, 192 in, 240 in (8 ft to 20 ft)
Columns 3 in by 1-5/8 in, or 3 in by 3 in
Gauge 14 gauge, with one 13 gauge frame at 42 in by 144 in

The heavier 3 in by 3 in column supports greater loads, and thicker steel generally supports more. Upright capacity governs the whole bay and changes with beam spacing, so do not infer it from the gauge or the column size. Tell us your beam elevations and ask for the rated capacity at that spacing. See Husky upright frames.

MECO structural frames

The MECO structural frames publish capacities with their condition. The 3 in channel frames are listed at a maximum of 34,800 lb per bay when vertical beam spacing does not exceed 60 in, and the 4 in frames at up to 52,200 lb per bay under the same condition. The 3 in frames have 3 in by 3 in base plates. The 4 in frames have 4 in by 3 in base plates with a 9/16 in anchor hole and beam holes every 2 in. See pallet racking systems.

Section Six

Beams, and the per-pair point

Capacity is per pair. Price is not always.

Short answer: Count two beams per level. Pick the beam length from the pallet widths plus clearance, then pick the profile for the capacity.

A beam level is two beams, front and back. Every capacity listed for a step beam is for the pair working together.

Check the unit on the price

On our listings, roll-formed step beams are priced each and rated per pair, and MECO structural beams are priced per pair. When you check a quote, count the beams: a three-level bay needs six.

The 4.32 in profile at four lengths, as listed
Model Length Capacity per pair
IBX43096 96 in 6,270 lb
IBX43108 108 in 5,060 lb
IBX43120 120 in 4,190 lb
IBX43144 144 in 3,020 lb

The same profile 48 in longer carries less than half. If a bay needs both length and capacity, choose a taller profile.

Worked example: beam length from pallet width

The rule on the beam listings: for two pallets wide, add at least 10 in to the combined pallet width. For three pallets wide, add at least 14 in.

Beam length
Pallets across the beam Math Beam to order
Two pallets with the 40 in side across 40 + 40 + 10 = 90 in 96 in
Two pallets with the 48 in side across 48 + 48 + 10 = 106 in 108 in
Three pallets with the 40 in side across 40 + 40 + 40 + 14 = 134 in 144 in

Roll-formed beams are listed at 48 in, 96 in, 108 in, 120 in and 144 in. Structural beams are listed in more lengths. See Husky step beams.

Section Seven

Decking, and how many per level

The deck count follows the beam length.

Short answer: Divide the beam length by the deck width and round down. Deck capacity drops as the rack gets deeper and rises with a fourth support channel.

Decks per level = beam length ÷ deck width, rounded down
48 in beam
One 46 in deck
96 in beam
Two 46 in decks, covering 92 in
108 in beam
Two 52 in decks, covering 104 in
144 in beam
Three 46 in decks, covering 138 in

The decks do not quite fill the beam, and the installer spaces out the remainder. If you store anything small enough to fall through a gap, tell us when you ask for the quote.

Listed wire deck capacities, evenly spread load
Deck depth Three channels (A3) Four channels (A4)
36 in 3,250 lb 3,900 lb
42 in 2,610 lb 3,150 lb
48 in 2,100 lb 2,630 lb

These are listed against ANSI MH26.2 for evenly spread static loads. A drum, a machine base on feet or a partial pallet concentrates the load, and the deck will not carry its rated figure. Nobody should stand on wire decking. See Husky wire decking and welded wire decking.

Solid and perforated decking

The Little Giant solid steel rack decking is listed with a 14 gauge surface on 12 gauge channels for 1-5/8 in step beams, with 1-1/2 in waterfalls front and back, at 3,000 lb per section, and a minimum order of ten pieces. Perforated steel decking is also listed. Open wire lets sprinkler water through to the lower levels. Solid decking blocks it, so ask your fire protection engineer before you choose it.

Section Eight

Crossbars, row spacers and wall ties

Three small parts that are easy to leave off the order.

Short answer: Order crossbars to the rack depth, row spacers to the flue space, and wall ties to the gap between the rack and the wall.

Crossbars

Crossbars sit between the two beams of a level. They keep pallets from slipping through, support undersized loads and back up decking. They are listed at 36 in, 42 in and 48 in to match the rack depth. How many a level needs depends on the load, so describe the load when you ask for a quote. MECO structural racks use drop-in cross support bars matched to the beam channel and rack depth.

Row spacers

Row spacers bolt between the frames of back-to-back rows and hold the flue space open. Listed at 6 in, 8 in, 12 in and 18 in.

Wall ties

Wall ties tie a single row to a building wall. Listed at 6 in, 8 in and 12 in, chosen by the gap between the upright and the wall.

Count by frame position, not by bay

Spacers and ties attach at frames. An eleven-frame run has eleven positions. How many go at each position depends on the frame height, so confirm that on the quote.

Section Nine

Protection

Low-cost parts that prevent the expensive failure.

Short answer: Protect the aisle-facing columns and the row ends. Mount protectors with a gap so the truck hits the protector first.

Protection options as listed
Type What it protects Listed detail
Wrap-around post protectors One upright column 12 in and 18 in high
Structural upright protectors Uprights on structural frames 12 in, 18 in and 24 in high, for 3 in or 4 in uprights, installed offset from the frame
Rack end protectors The end frame at an aisle 42 in and 48 in long, medium and heavy duty, fixed with four or five wedge anchors sold separately
Rack guards with bumpers The upright, with a rubber face About 12 in to 36 in high
Fluted mesh safety backing The aisle or work area behind the rack 8 gauge welded wire, panels from 8 ft by 3 ft to 12 ft by 5 ft, mounted flush or offset up to 6 in

See pallet rack upright protection and WireCrafters rack safety backing. Rack end protectors need their own anchors, so add them to the order. Building column guards are a different product in different sizes. Our barriers and guarding guide covers guard rail and bollards.

Section Ten

Roll-formed or structural

How the two order differently.

Short answer: Roll-formed beams drop in and lock. Structural beams bolt on. The two systems do not mix in one run.

How the two order
Roll-formed teardrop Structural channel
Beam connection Teardrop with a locking tab and a safety clip Two high-strength bolts per beam end
Beam price on our listings Each Per pair
Frame capacity Ask us for the rating at your beam spacing Listed, with a beam spacing condition
Beam lengths listed 48 in, 96 in, 108 in, 120 in, 144 in 48 in to 144 in in more steps
Beam adjustment 2 in 2 in
Do not mix the two in one run

Teardrop beams and bolted structural beams are not interchangeable, and neither are the frames. If you are adding to existing rack, identify the make and model before you order.

Section Eleven

What is not in the box

Two items every installation needs.

Short answer: Floor anchors and load plaques are separate. Work out the anchor count before the rack arrives.

Floor anchors

ANSI MH16.1 calls for a base plate and anchors on every column. Count two columns per frame, at least one anchor per column, times the number of frames. Eleven frames need at least 22. The anchor size and number are set by the rack design and the slab. Add the separate anchors for rack end protectors.

Load plaques

ANSI MH16.1 calls for a plaque showing the rack capacity. If you install new rack or move beams on existing rack, the plaque is part of the job. The racking guide covers what goes on it.

Minimum quantities and freight

Solid steel decking has a listed minimum of ten pieces. Rack parts are heavy and bulky, so put the whole project on one order instead of paying freight twice.

Section Twelve

A worked bill of materials

Ten bays, three levels, built from first principles.

Short answer: Start with the beam length. Everything else follows from it.

A ten-bay single row against a wall, 42 in deep and 144 in high, two pallets per level with the 48 in side across the beam, three beam levels per bay, wire decked.

Two 48 in pallets are 96 in, plus the 10 in allowance, which is 106 in. The next beam is 108 in. Two 52 in decks cover 104 in of it.

Bill of materials
Item Math Quantity
Upright frames 10 bays + 1 11
Step beams, 108 in 2 per level × 3 levels × 10 bays 60
Wire decks, 52 in wide 2 per level × 3 levels × 10 bays 60
Wall ties 11 frame positions Confirm the number per position
Post protectors Aisle-facing columns on 11 frames 11
Rack end protectors Both ends of the run 2
Floor anchors 2 columns × 11 frames, plus protector anchors 22 or more
Load plaque One for the configuration At least 1

Run length: 10 × 108 in + 11 × 3 in = 1,113 in, or 92 ft 9 in. Level load: each 108 in level has to carry two pallets, so compare the two pallet weights to the beam pair rating, and the total of all three levels to the frame rating at your beam spacing.

Section Thirteen

Common and costly mistakes

Nearly all of them are counting mistakes.

Short answer: Count frames as bays plus one, beams as two per level, and decks by beam length.

Ordering two uprights per bay

Adjacent bays share a frame.

Pricing one beam per level

A level is a pair.

Ordering 96 in beams for two 48 in pallets

Add at least 10 in. That is a 108 in beam.

Ordering decks by bay depth alone

The count follows the beam length.

Forgetting the 3 in per upright

Eleven uprights add 33 in to a ten-bay run.

Inferring frame capacity from the gauge

Ask for the rating at your beam spacing.

Leaving off anchors, plaques, spacers or ties

None of them come with the frames and beams.

Mixing teardrop and structural parts

They do not interchange.

Section Fourteen

Frequently asked questions

What comes up most often on component orders.

How many uprights do I need for a row of pallet rack?

The number of bays plus one. Adjacent bays share an upright frame, so a ten-bay row needs eleven frames.

What is the difference between a starter and an add-on?

A starter unit has two uprights and stands alone or begins a row. An add-on has one upright and uses the last upright of the bay before it.

Is beam capacity per beam or per pair?

Per pair. A level is a front beam and a back beam working together, and the listed capacity is for both.

What beam length do I need for two pallets?

Add at least 10 in to the combined pallet width. Two pallets with the 40 in side across need a 96 in beam. Two with the 48 in side across need a 108 in beam.

How many wire decks per level?

Divide the beam length by the deck width and round down. A 96 in beam takes two 46 in decks, a 108 in beam takes two 52 in decks, and a 144 in beam takes three 46 in decks.

What do A3 and A4 mean on wire decking?

The number of front-to-back support channels under the deck. A four-channel deck carries more than a three-channel deck of the same size.

How do I read a Husky upright part number?

IU, then the column code, depth and height. IU18420144 is a 3 in by 1-5/8 in column, 42 in deep and 144 in high.

What are row spacers for?

They tie back-to-back rows together and keep the flue space between them open for sprinkler water.

Do anchors come with the rack?

No. Floor anchors are separate. ANSI MH16.1 calls for every column to be anchored.

Can I mix roll-formed and structural components?

No. Teardrop beams and bolted structural beams and their frames are not interchangeable.

How long is a rack run?

Add the beam lengths and 3 in for each upright. Ten bays of 108 in beams with eleven uprights is 1,113 in, or 92 ft 9 in.

Section Fifteen

Quick-reference tables

The counting rules on one screen.

Counting rules
Item Rule
Upright frames Bays + 1
Beams 2 × levels × bays
Beam length, two pallets Pallet widths + at least 10 in
Beam length, three pallets Pallet widths + at least 14 in
Decks per level Beam length ÷ deck width, rounded down
Run length Beam lengths + 3 in per upright
Anchors At least one per column, two columns per frame
Spacers and wall ties By frame position
What we list
Component Listing
Upright frames Husky upright frames
Step beams Husky step beams
Wire decking Husky wire decking, welded wire decking
Steel decking Solid, perforated
Crossbars, spacers, ties Crossbars, row spacers, wall ties
Protection and backing Upright protection, fluted mesh backing, flue stops
Structural rack Pallet racking systems
Before you order

Send us the number of bays, the frame depth and height, the beam elevations, the pallet size and weight, and whether the row is single, back-to-back or against a wall. We will check the counts and the capacities.

About the author. Tom McGovern has worked in the industrial material handling industry since 1981, bringing over 45 years of hands-on experience helping businesses select the right equipment for their applications. His expertise includes specifying and quoting upright frames, step beams, wire decking, crossbars and rack protection.

Questions about this guide? Call 866-333-0728 to speak with an experienced material handling specialist.

Ready for a quote?

Send us these details and a material handling specialist will reply, typically within one business day.

  • Dimensions
    Size of the load and the space it goes in
  • Load
    Weight per item, shelf or level
  • Quantity
    How many units you need
  • Delivery ZIP code
    For freight pricing
  • Drawing
    A sketch, photo or spec sheet, if you have one
Get a Fast Quote Call 866-333-0728

Send us the run and we will check the counts

Bays, depth, height, beam elevations and pallet size. We will build the bill of materials with you. Quotes are reviewed by material handling specialists, typically within one business day.

866-333-0728

Browse pallet rack components at custommhs.com

No bots. No guesswork. Real experts.

Sources

ANSI MH16.1 and MH26.2 · Husky, MECO and Little Giant part numbers, sizes and capacities as published on CustomMHS product listings.

Disclaimer. This guide is educational content and reflects the opinion and general experience of CustomMHS. It is not a structural design. Rack capacity depends on the engineered configuration, the floor slab and the location. Have the capacity confirmed for your layout and beam spacing before ordering. Reviewed November 2026.