A narrow scope on purpose, because the engineering is covered in the guide next door.
Quick answers
- Uprights = number of bays + 1. A ten-bay row needs eleven upright frames, not twenty.
- Beams are rated per pair. A three-level bay needs six beams. Check whether the price on the quote is each or per pair.
- For two pallets side by side, add at least 10 in to the combined pallet width. Two 48 in pallets need a 108 in beam, not a 96 in beam.
- Decks per level depend on the beam length: one 46 in deck on a 48 in beam, two on a 96 in beam, three on a 144 in beam.
- Floor anchors and load plaques are not in the box. Plan for both.
Our Pallet Racking and Storage Racks guide covers the engineering: why every capacity has a condition, how beam and frame capacity change, deflection, anchoring, load plaques, inspection and ANSI MH16.1. If you have not settled the rack type, bay size or capacity, start there.
This guide starts once those decisions are made and you are looking at a component list, working out what goes on the purchase order. To browse, see pallet rack components.
Please read this part
This guide is educational and reflects the opinion and general experience of CustomMHS as an equipment distributor. It is not a structural design. Rack capacity depends on the engineered configuration, the floor and the location. Part numbers, sizes and capacities are from the CustomMHS listings. Confirm the current data sheet for your exact model before you order.
Section Two
What a rack run is made of
Eight things, and only three of them are obvious.
Short answer: Frames, beams and decking make the rack. Crossbars, row spacers, wall ties, protection and anchors make it a working installation.
The parts of a rack run
| Component |
What it does |
Quantity is set by |
| Upright frames |
The vertical structure: two columns with bracing |
Number of bays, plus one |
| Step beams |
The horizontal load members, two per level |
Levels and bays |
| Decking |
Supports the load across the beams. Wire, solid or perforated |
Beam length |
| Crossbars |
Extra support between the beams of a level |
What you store |
| Row spacers |
Tie back-to-back rows together and hold the flue space open |
Frame positions in a back-to-back run |
| Wall ties |
Tie a single row to a building wall |
Frame positions along the wall |
| Post protectors and end guards |
Take the fork truck impact instead of the upright |
Aisle exposure |
| Floor anchors |
Fix the base plates to the slab |
Every column |
The flue space is a fire code question
The flue is the gap between back-to-back rows. Fire codes call for it to stay open so sprinkler water reaches the lower levels, which is why row spacers are chosen by the flue space you need. Confirm the dimension with your fire protection engineer or building official. A flue stop keeps pallets from being pushed into that space.
Section Three
Starter and add-on: the quantity math
The most common ordering error in this category.
Short answer: The first bay needs two frames. Every bay after it shares a frame and needs one more.
A ten-bay run is one starter and nine add-ons: eleven uprights, not twenty.
Listed pre-configured units, showing the pattern
| Unit |
Uprights |
Beams |
Decks |
| Three-level starter, 48 in beams |
2 |
6 |
3 |
| Two-level add-on, 96 in beams |
1 |
4 |
4 |
| Three-level starter, 96 in beams, no decking |
2 |
6 |
None |
Worked example: how long is the run?
Each upright adds 3 in to the run, per the unit listings. For ten bays of 108 in beams:
Run length
| Step |
Math |
Result |
| Beams |
10 × 108 in |
1,080 in |
| Uprights |
11 × 3 in |
33 in |
| Total |
1,080 in + 33 in |
1,113 in, or 92 ft 9 in |
Check that against the wall-to-wall dimension, with working room at the ends, before you order. Pre-configured units and loose components can both build the same run. Units are convenient. Loose components let you set different heights or capacities by level.
Section Four
Reading the part numbers
Each family builds its specification into the part number.
Short answer: On Husky uprights, IU is followed by a column code, depth and height. On step beams, IB is followed by a series letter, profile height and length.
The five schemes
| Family |
Pattern |
Worked example |
| Roll-formed uprights |
IU + column code + depth + height |
IU24480192 is a 3 in by 3 in column, 48 in deep, 192 in high |
| Step beams |
IB + series letter + profile height + length |
IBX43144 is X series, 4.32 in profile, 144 in long |
| Wire decking |
Depth + width + A3 or A4 |
4846A3 is 48 in by 46 in with three support channels |
| Structural uprights |
SF3 or SF4 + depth + height in feet |
SF4-4824 is 4 in channel, 48 in deep, 24 ft high |
| Structural beams |
2SB + channel depth + length |
2SB5-48 is a 5 in channel beam, 48 in long |
The beam series letters
Three profile tiers are listed. IBX covers 3.0 in to 4.85 in profiles, IBN is 5.5 in and IBH is 6.0 in. At the same length, a taller profile carries much more. A 144 in IBX43144 is listed at 3,020 lb per pair, and a 144 in IBH60144 at 8,300 lb per pair.
Pre-configured unit codes
Starter and add-on units read like 42x144x48x7383-3SW: 42 in deep, 144 in high, 48 in beams, a beam capacity figure, 3 levels, Starter, Wire decking. An A in place of the S is an add-on, and no W means no decking.
Matching loose beams to existing units
If you are adding loose beams to a run of pre-configured units, have the capacity for the exact beam part number confirmed on the quote.
Section Five
Uprights
Four decisions: depth, height, column size and gauge.
Short answer: Depth and height come from your pallet and building. Column and gauge come from the load. Ask for the frame capacity at your beam spacing in writing.
Husky roll-formed upright options as listed
| Specification |
Listed options |
| Depths |
36 in, 42 in, 48 in |
| Heights |
96 in, 120 in, 144 in, 192 in, 240 in (8 ft to 20 ft) |
| Columns |
3 in by 1-5/8 in, or 3 in by 3 in |
| Gauge |
14 gauge, with one 13 gauge frame at 42 in by 144 in |
The heavier 3 in by 3 in column supports greater loads, and thicker steel generally supports more. Upright capacity governs the whole bay and changes with beam spacing, so do not infer it from the gauge or the column size. Tell us your beam elevations and ask for the rated capacity at that spacing. See Husky upright frames.
MECO structural frames
The MECO structural frames publish capacities with their condition. The 3 in channel frames are listed at a maximum of 34,800 lb per bay when vertical beam spacing does not exceed 60 in, and the 4 in frames at up to 52,200 lb per bay under the same condition. The 3 in frames have 3 in by 3 in base plates. The 4 in frames have 4 in by 3 in base plates with a 9/16 in anchor hole and beam holes every 2 in. See pallet racking systems.
Section Six
Beams, and the per-pair point
Capacity is per pair. Price is not always.
Short answer: Count two beams per level. Pick the beam length from the pallet widths plus clearance, then pick the profile for the capacity.
A beam level is two beams, front and back. Every capacity listed for a step beam is for the pair working together.
Check the unit on the price
On our listings, roll-formed step beams are priced each and rated per pair, and MECO structural beams are priced per pair. When you check a quote, count the beams: a three-level bay needs six.
The 4.32 in profile at four lengths, as listed
| Model |
Length |
Capacity per pair |
| IBX43096 |
96 in |
6,270 lb |
| IBX43108 |
108 in |
5,060 lb |
| IBX43120 |
120 in |
4,190 lb |
| IBX43144 |
144 in |
3,020 lb |
The same profile 48 in longer carries less than half. If a bay needs both length and capacity, choose a taller profile.
Worked example: beam length from pallet width
The rule on the beam listings: for two pallets wide, add at least 10 in to the combined pallet width. For three pallets wide, add at least 14 in.
Beam length
| Pallets across the beam |
Math |
Beam to order |
| Two pallets with the 40 in side across |
40 + 40 + 10 = 90 in |
96 in |
| Two pallets with the 48 in side across |
48 + 48 + 10 = 106 in |
108 in |
| Three pallets with the 40 in side across |
40 + 40 + 40 + 14 = 134 in |
144 in |
Roll-formed beams are listed at 48 in, 96 in, 108 in, 120 in and 144 in. Structural beams are listed in more lengths. See Husky step beams.
Section Seven
Decking, and how many per level
The deck count follows the beam length.
Short answer: Divide the beam length by the deck width and round down. Deck capacity drops as the rack gets deeper and rises with a fourth support channel.
The decks do not quite fill the beam, and the installer spaces out the remainder. If you store anything small enough to fall through a gap, tell us when you ask for the quote.
Listed wire deck capacities, evenly spread load
| Deck depth |
Three channels (A3) |
Four channels (A4) |
| 36 in |
3,250 lb |
3,900 lb |
| 42 in |
2,610 lb |
3,150 lb |
| 48 in |
2,100 lb |
2,630 lb |
These are listed against ANSI MH26.2 for evenly spread static loads. A drum, a machine base on feet or a partial pallet concentrates the load, and the deck will not carry its rated figure. Nobody should stand on wire decking. See Husky wire decking and welded wire decking.
Solid and perforated decking
The Little Giant solid steel rack decking is listed with a 14 gauge surface on 12 gauge channels for 1-5/8 in step beams, with 1-1/2 in waterfalls front and back, at 3,000 lb per section, and a minimum order of ten pieces. Perforated steel decking is also listed. Open wire lets sprinkler water through to the lower levels. Solid decking blocks it, so ask your fire protection engineer before you choose it.
Section Eight
Crossbars, row spacers and wall ties
Three small parts that are easy to leave off the order.
Short answer: Order crossbars to the rack depth, row spacers to the flue space, and wall ties to the gap between the rack and the wall.
Crossbars
Crossbars sit between the two beams of a level. They keep pallets from slipping through, support undersized loads and back up decking. They are listed at 36 in, 42 in and 48 in to match the rack depth. How many a level needs depends on the load, so describe the load when you ask for a quote. MECO structural racks use drop-in cross support bars matched to the beam channel and rack depth.
Row spacers
Row spacers bolt between the frames of back-to-back rows and hold the flue space open. Listed at 6 in, 8 in, 12 in and 18 in.
Wall ties
Wall ties tie a single row to a building wall. Listed at 6 in, 8 in and 12 in, chosen by the gap between the upright and the wall.
Count by frame position, not by bay
Spacers and ties attach at frames. An eleven-frame run has eleven positions. How many go at each position depends on the frame height, so confirm that on the quote.
Section Nine
Protection
Low-cost parts that prevent the expensive failure.
Short answer: Protect the aisle-facing columns and the row ends. Mount protectors with a gap so the truck hits the protector first.
Protection options as listed
| Type |
What it protects |
Listed detail |
| Wrap-around post protectors |
One upright column |
12 in and 18 in high |
| Structural upright protectors |
Uprights on structural frames |
12 in, 18 in and 24 in high, for 3 in or 4 in uprights, installed offset from the frame |
| Rack end protectors |
The end frame at an aisle |
42 in and 48 in long, medium and heavy duty, fixed with four or five wedge anchors sold separately |
| Rack guards with bumpers |
The upright, with a rubber face |
About 12 in to 36 in high |
| Fluted mesh safety backing |
The aisle or work area behind the rack |
8 gauge welded wire, panels from 8 ft by 3 ft to 12 ft by 5 ft, mounted flush or offset up to 6 in |
See pallet rack upright protection and WireCrafters rack safety backing. Rack end protectors need their own anchors, so add them to the order. Building column guards are a different product in different sizes. Our barriers and guarding guide covers guard rail and bollards.
Section Ten
Roll-formed or structural
How the two order differently.
Short answer: Roll-formed beams drop in and lock. Structural beams bolt on. The two systems do not mix in one run.
How the two order
|
Roll-formed teardrop |
Structural channel |
| Beam connection |
Teardrop with a locking tab and a safety clip |
Two high-strength bolts per beam end |
| Beam price on our listings |
Each |
Per pair |
| Frame capacity |
Ask us for the rating at your beam spacing |
Listed, with a beam spacing condition |
| Beam lengths listed |
48 in, 96 in, 108 in, 120 in, 144 in |
48 in to 144 in in more steps |
| Beam adjustment |
2 in |
2 in |
Do not mix the two in one run
Teardrop beams and bolted structural beams are not interchangeable, and neither are the frames. If you are adding to existing rack, identify the make and model before you order.
Section Eleven
What is not in the box
Two items every installation needs.
Short answer: Floor anchors and load plaques are separate. Work out the anchor count before the rack arrives.
Floor anchors
ANSI MH16.1 calls for a base plate and anchors on every column. Count two columns per frame, at least one anchor per column, times the number of frames. Eleven frames need at least 22. The anchor size and number are set by the rack design and the slab. Add the separate anchors for rack end protectors.
Load plaques
ANSI MH16.1 calls for a plaque showing the rack capacity. If you install new rack or move beams on existing rack, the plaque is part of the job. The racking guide covers what goes on it.
Minimum quantities and freight
Solid steel decking has a listed minimum of ten pieces. Rack parts are heavy and bulky, so put the whole project on one order instead of paying freight twice.
Section Twelve
A worked bill of materials
Ten bays, three levels, built from first principles.
Short answer: Start with the beam length. Everything else follows from it.
A ten-bay single row against a wall, 42 in deep and 144 in high, two pallets per level with the 48 in side across the beam, three beam levels per bay, wire decked.
Two 48 in pallets are 96 in, plus the 10 in allowance, which is 106 in. The next beam is 108 in. Two 52 in decks cover 104 in of it.
Bill of materials
| Item |
Math |
Quantity |
| Upright frames |
10 bays + 1 |
11 |
| Step beams, 108 in |
2 per level × 3 levels × 10 bays |
60 |
| Wire decks, 52 in wide |
2 per level × 3 levels × 10 bays |
60 |
| Wall ties |
11 frame positions |
Confirm the number per position |
| Post protectors |
Aisle-facing columns on 11 frames |
11 |
| Rack end protectors |
Both ends of the run |
2 |
| Floor anchors |
2 columns × 11 frames, plus protector anchors |
22 or more |
| Load plaque |
One for the configuration |
At least 1 |
Run length: 10 × 108 in + 11 × 3 in = 1,113 in, or 92 ft 9 in. Level load: each 108 in level has to carry two pallets, so compare the two pallet weights to the beam pair rating, and the total of all three levels to the frame rating at your beam spacing.
Section Thirteen
Common and costly mistakes
Nearly all of them are counting mistakes.
Short answer: Count frames as bays plus one, beams as two per level, and decks by beam length.
Ordering two uprights per bay
Adjacent bays share a frame.
Pricing one beam per level
A level is a pair.
Ordering 96 in beams for two 48 in pallets
Add at least 10 in. That is a 108 in beam.
Ordering decks by bay depth alone
The count follows the beam length.
Forgetting the 3 in per upright
Eleven uprights add 33 in to a ten-bay run.
Inferring frame capacity from the gauge
Ask for the rating at your beam spacing.
Leaving off anchors, plaques, spacers or ties
None of them come with the frames and beams.
Mixing teardrop and structural parts
They do not interchange.
Section Fourteen
Frequently asked questions
What comes up most often on component orders.
How many uprights do I need for a row of pallet rack?
The number of bays plus one. Adjacent bays share an upright frame, so a ten-bay row needs eleven frames.
What is the difference between a starter and an add-on?
A starter unit has two uprights and stands alone or begins a row. An add-on has one upright and uses the last upright of the bay before it.
Is beam capacity per beam or per pair?
Per pair. A level is a front beam and a back beam working together, and the listed capacity is for both.
What beam length do I need for two pallets?
Add at least 10 in to the combined pallet width. Two pallets with the 40 in side across need a 96 in beam. Two with the 48 in side across need a 108 in beam.
How many wire decks per level?
Divide the beam length by the deck width and round down. A 96 in beam takes two 46 in decks, a 108 in beam takes two 52 in decks, and a 144 in beam takes three 46 in decks.
What do A3 and A4 mean on wire decking?
The number of front-to-back support channels under the deck. A four-channel deck carries more than a three-channel deck of the same size.
How do I read a Husky upright part number?
IU, then the column code, depth and height. IU18420144 is a 3 in by 1-5/8 in column, 42 in deep and 144 in high.
What are row spacers for?
They tie back-to-back rows together and keep the flue space between them open for sprinkler water.
Do anchors come with the rack?
No. Floor anchors are separate. ANSI MH16.1 calls for every column to be anchored.
Can I mix roll-formed and structural components?
No. Teardrop beams and bolted structural beams and their frames are not interchangeable.
How long is a rack run?
Add the beam lengths and 3 in for each upright. Ten bays of 108 in beams with eleven uprights is 1,113 in, or 92 ft 9 in.
Section Fifteen
Quick-reference tables
The counting rules on one screen.
Counting rules
| Item |
Rule |
| Upright frames |
Bays + 1 |
| Beams |
2 × levels × bays |
| Beam length, two pallets |
Pallet widths + at least 10 in |
| Beam length, three pallets |
Pallet widths + at least 14 in |
| Decks per level |
Beam length ÷ deck width, rounded down |
| Run length |
Beam lengths + 3 in per upright |
| Anchors |
At least one per column, two columns per frame |
| Spacers and wall ties |
By frame position |
Before you order
Send us the number of bays, the frame depth and height, the beam elevations, the pallet size and weight, and whether the row is single, back-to-back or against a wall. We will check the counts and the capacities.
About the author. Tom McGovern has worked in the industrial material handling industry since 1981, bringing over 45 years of hands-on experience helping businesses select the right equipment for their applications. His expertise includes specifying and quoting upright frames, step beams, wire decking, crossbars and rack protection.