Section One
What the mesh is stopping
Mesh opening size and standoff distance are the same decision. Most buyers make only half of it.
Quick answers
- For security, the question is whether someone can get through or unbolt the cage. For machine guarding, the question is how far an arm reaches through the mesh.
- A hand and forearm pass through 2 in mesh. Under ISO 13857, a guard with openings that size has to stand about 33-1/2 in back from the hazard.
- Woven 2 in by 1 in mesh in a heavy frame is the heavy duty choice. Welded 2 in by 2 in mesh is the medium duty choice. Both are 10 gauge.
- A cage for Schedule III to V controlled substances has to meet the construction rules in 21 CFR 1301.72. Schedule I and II need a safe or vault.
- Check sprinkler clearance above a cage with a ceiling, and give anyone working inside a way out that needs no key.
For security, a fence either keeps someone out or it does not. For safety, the question is different. It is whether a person can reach through the fence, and how far the arm gets.
ISO 13857 answers this. It gives minimum distances between a guard and a hazard for each size of opening, based on how far fingers, hands and arms reach.
ISO 13857, reaching through square openings, shown in inches
| Opening size |
Minimum distance to the hazard |
| Up to about 1/2 in |
About 3-1/8 in |
| Over 1/2 in, up to about 1-1/8 in |
About 4-3/4 in |
| Over 1-1/8 in, up to about 1-1/2 in |
About 7-7/8 in |
| Over 1-1/2 in, up to about 4-3/4 in |
About 33-1/2 in |
Two inch mesh does not stop an arm
Standard 2 in mesh is an excellent security barrier and a poor close-range safety guard. If you are fencing a robot or a machine, plan on about 33-1/2 in of standoff, or use a finer mesh so the fence can sit closer. Wire gauge does not change this. Gauge is how hard the wire is to cut. Opening size is what fits through it.
Rectangular mesh, such as 2 in by 1 in, is judged by its narrow dimension as a slot, and the standard treats short slots differently from square openings. Have the distance for your exact mesh confirmed against ISO 13857 and your risk assessment. Our barriers and machine guarding guide covers safe distance and OSHA 1910.212.
Please read this part
This guide is educational and reflects the opinion and general experience of CustomMHS as an equipment distributor. It is not a risk assessment, a security assessment or compliance advice. Machine guarding distances depend on your hazard, and controlled substance storage is assessed by the DEA for your registration. Confirm the current data sheet for your exact model before you order.
Section Two
Woven or welded wire
Two ways to make a panel, with different behavior when someone attacks it.
Short answer: Woven wire in a heavy angle frame for high security and rough use. Welded wire for general inventory control and separation.
Heavy duty
Woven wire
The wires are woven, then the panel is welded into a hot-rolled angle frame. The WireCrafters Style 840 is listed as 10 gauge wire in a 2 in by 1 in mesh, with stiffener bars on larger panels. One cut does not open a hole, because the weave around it holds.
Medium duty
Welded wire
The wires are welded at each crossing into a rigid sheet. The WireCrafters welded wire RapidWire system is listed as 10 gauge in a 2 in by 2 in mesh on a 1-1/4 in by 1-1/4 in by 1/8 in angle frame. Lighter and faster to assemble.
Same gauge, different products
Both are 10 gauge, so comparing quotes by gauge tells you little. Ask for the mesh pattern, the frame size and the construction, in that order.
- Woven, 2 in by 1 in: controlled substances, high-value stock, tool cribs in rough areas, anywhere a fork truck may touch it.
- Welded, 2 in by 2 in: inventory control, storage cages, separating areas, lighter security.
- Neither: when you need privacy or dust control. A wire partition is see-through by design.
Section Three
The frame, the posts and the hardware
A cage is defeated at its weakest fastener, not through its strongest panel.
Short answer: Ask which side the fasteners are on. Hardware that can be reached from outside can be removed from outside.
What to look at beyond the mesh
| Part |
Listed on the Style 840 |
Why it matters |
| Hardware |
3/8 in hardware, reachable only from inside the cage |
A panel bolted from the aisle side can be unbolted with a socket set, with no sign of a break-in |
| Posts |
2 in square, 14 gauge steel tube |
Square tube resists twisting. Post spacing is specified, not a convenience |
| Floor |
Panels mount flush to the floor, with concrete floor anchors |
A gap at the bottom is a way in. On an uneven slab this needs attention at installation |
Two quotes can match on gauge, mesh and height
and one cage can still be taken apart from the aisle. If a supplier cannot tell you which side the fasteners are on, that is your answer.
Section Four
The DEA cage specification
The rare case where the product specification is written into federal regulation.
Short answer: For Schedule III, IV and V controlled substances, 21 CFR 1301.72(b) sets the wire gauge, mesh size, post spacing, reinforcement, ceiling, door and alarm.
Cage requirements in 21 CFR 1301.72(b)
| Element |
Requirement |
| Walls |
Steel fabric of not less than No. 10 gauge, mounted on steel posts |
| Mesh |
Openings of not more than 2-1/2 in across the square |
| Posts |
At least 1 in in diameter, set in concrete or installed with lag bolts that are pinned or brazed |
| Post spacing |
No more than 10 ft apart |
| Reinforcement |
Horizontal 1-1/2 in reinforcements every 60 in |
| Ceiling |
A mesh ceiling of the same material, or walls that reach and are securely attached to the structural ceiling |
| Door |
No. 10 gauge steel fabric on a metal door frame in a metal door flange |
| Alarm |
On unauthorized entry, a signal to a central station protection agency or a police agency |
A cage does not cover every schedule
A wire cage addresses Schedule III, IV and V. Schedule I and II substances call for a safe or vault under the same section. If you handle both, you need both.
The WireCrafters DEA drug storage cage is built to those numbers: 10 gauge wire in a 2 in by 1 in mesh, 2 in square steel posts no more than 10 ft apart, horizontal bars every 5 ft, self-closing and self-locking doors, and 3/8 in hardware that cannot be reached from outside. It is listed for Schedule III through V storage under 21 CFR 1301.72 to 1301.76.
Price the ceiling
You can run the walls to the building structure or add a mesh ceiling. In a tall building the mesh ceiling is usually the easier route. Ceilings are listed with clear spans up to 30 ft.
Doors
Self-closing, self-locking doors are the usual answer. A door propped open defeats them, so plan the access for how people really work.
Orientation, not compliance
The DEA assesses controlled substance security for your registration and location, and other sections of Part 1301 apply. Confirm your requirements with the agency and your compliance counsel before you order.
Section Five
Configurations, heights and doors
You buy the walls you do not already have.
Short answer: Count the building walls you can use, pick one of three listed heights, and choose the door by the clearance you have.
Worked example: a 12 ft by 20 ft crib
Feet of partition to buy
| Configuration |
Math |
Partition needed |
| 4 walls, free standing |
12 + 20 + 12 + 20 |
64 ft |
| 3 walls, long side on a building wall |
12 + 20 + 12 |
44 ft |
| 2 walls, in a building corner |
12 + 20 |
32 ft |
| 1 wall, closing off an alcove 20 ft wide |
20 |
20 ft |
Check what the building wall is made of
A one, two or three wall layout assumes the building wall is a barrier. Drywall on studs is not. If the contents matter, verify the wall or buy the extra side.
Listed heights are 8 ft 5-1/4 in, 10 ft 5-1/4 in and 12 ft 5-1/4 in, with panel widths from 1 ft to 10 ft in 1 ft steps. Lay out in those increments.
Door types
| Door |
When to use it |
| Hinged |
The default. Needs room to swing |
| Double hinged |
Wide openings for a pallet jack or cart |
| Sliding |
No room to swing. Uses wall length |
| Vertical rise |
No swing room and no spare wall, with headroom available |
The door is the part that wears. Everything else stands still, and the door cycles thousands of times a year. Our Style 840 guide covers panels, posts and doors in detail.
Section Six
Locks and access control
The lock is a policy decision, and some of the options do not lock.
Short answer: A latch holds a door closed. It does not secure it. Choose the lock by how many people need access.
Read the description
Two standard options, the thumb-turn latch and the door knob entry set, are listed as "latches only; does not lock." They suit a partition that separates areas. They are wrong for a cage that protects anything of value.
Lock options as listed
| Lock |
What it does |
| Key lock with recessed thumb turn inside |
Cylinder key outside, thumb turn inside. For hinged or sliding doors |
| Key lock with lever handle inside |
The same lock with an ADA lever handle, for hinged doors |
| Push bar |
Full-width bar on the inside for exit |
| Alarm lock |
Sounds a battery-powered alarm when opened |
| Ten-digit keypad |
Works an electric strike or magnetic lock. Programmable for up to 64 codes |
| Keyless entry with lever handle |
Coded access with an accessible handle |
| Five-button coded lock |
Code or key entry |
| Card reader |
Works an electric strike or magnetic lock. Supplied with ten cards |
| Magnetic lock for sliding doors |
Holds the door closed electrically. Decide what it does when power fails |
See WireCrafters locks. A key lock is right for three named keyholders and wrong for forty people on three shifts, where keys get copied or the door gets propped. Individual codes or cards also give you a record of who went in.
Section Seven
Machine guard and robot fencing
The same kind of panel doing a different job under different rules.
Short answer: Set the fence line by the mesh opening and the hazard, keep panels close to the floor, and use an interlocked gate, not a key lock.
Security fencing keeps people away from things. Safety fencing keeps hazards away from people, and the consequence of getting it wrong is an injury. See WireCrafters machine guard fencing.
- Distance: with 2 in mesh, plan on about 33-1/2 in from the fence to the hazard, per section one. If the cell does not have that room, use a finer mesh or a different guard.
- Floor gap: ISO 13857 covers legs as well as arms. A large gap under the fence is an opening.
- Height: a fence that is too low can be reached over. The required height depends on the hazard height and the distance.
- The door: a cell door normally has to stop the hazard when it opens. That is an interlock wired to the machine's safety circuit. A key lock secures the cell and protects nobody.
Lift-out RapidGuard fencing lets a panel be lifted out instead of unbolted. On a cell where a machine is pulled out for service, that saves hours.
Fencing follows the risk assessment
This guide shows how mesh size drives distance. It cannot give you the required distance for your machine. Specify the fence from the risk assessment with your safety engineer.
Section Eight
Driver cages and dock control
A small enclosure that solves a traffic problem and a security problem at once.
Short answer: A driver cage gives visitors a place to wait that is not the fork truck lane, and a point to check in before going further.
A driver access cage creates a controlled entry at a dock or door. Drivers and vendors step in, check in and wait there, out of fork truck lanes and away from inventory.
Driver access cages as listed
| Model |
Configuration |
Size |
| MT2-33HD |
2-wall |
3 ft 4 in by 3 ft 4 in |
| MT3-33HD |
3-wall |
3 ft 4 in by 3 ft 4 in |
| MT2-46HD |
2-wall |
4 ft 4 in by 6 ft 4 in |
| MT3-56HD |
3-wall |
5 ft 6 in by 6 ft 4 in |
| MT2-88HD |
2-wall |
8 ft 6 in by 8 ft 4 in |
| MT3-88HD |
3-wall |
8 ft 6 in by 8 ft 4 in |
Benches are listed at 4 ft (MTB-4) and 8 ft (MTB-8) long. Doors are 3 ft or 4 ft hinged.
Worked example. The 3 ft 4 in square cage is about 11 sq ft. The 8 ft 6 in by 8 ft 4 in cage is about 71 sq ft, more than six times the floor area. A driver in a cramped cage is a driver who steps out of it, so when in doubt, size up.
Section Nine
Rack enclosures, rack backing and gates
Using structure you already own.
Short answer: If the stock is already on pallet rack, close the rack instead of building a room around it.
Rack enclosures
WireCrafters pallet rack enclosures fit wire panels and doors to the rack, turning bays into locked storage without giving up floor space.
Rack safety backing
Wire mesh rack backing on the back of a row keeps product from being pushed through into an aisle, walkway or work area behind it.
Server cages
Style 840 server cages enclose equipment that needs airflow and controlled access.
Gates
For openings that are closed only some of the time: folding security gates, pair gates, door gates and Vestil Expand-A-Gates. Pick the lightest gate that survives your conditions, because a gate that is hard to move gets left open.
An enclosure does not fix the rack
Panels on a rack do not change its capacity or repair damage. Our pallet racking guide covers rack inspection.
Section Ten
Sprinklers and getting out
Two ways a cage can create a problem in a building that was fine before.
Short answer: Leave the required clearance between a cage ceiling and the sprinklers, usually 18 in, and provide an exit that needs no key.
Worked example: sprinkler clearance
NFPA 13 generally calls for at least 18 in between the sprinkler deflector and the top of an obstruction below it. Your fire protection contractor will confirm the figure for your sprinklers and occupancy.
Lowest sprinkler deflector height over a cage with a ceiling, at 18 in clearance
| Cage height |
Math |
Deflector at or above |
| 8 ft 5-1/4 in |
+ 1 ft 6 in |
9 ft 11-1/4 in |
| 10 ft 5-1/4 in |
+ 1 ft 6 in |
11 ft 11-1/4 in |
| 12 ft 5-1/4 in |
+ 1 ft 6 in |
13 ft 11-1/4 in |
Check that on the drawing before you choose the height. A mesh ceiling lets water through, but the clearance still has to be checked.
Getting out
A locked enclosure that people work inside is a room, and a room needs a way out that does not need a key. That is what the push bar is for. Before you order, settle three things: does anyone work inside, how do they get out if the power fails, and does your building or fire official require exit hardware.
Section Eleven
Choosing by application
Find the row that matches your situation.
Short answer: Decide first whether the job is security or safety. Then the threat, the people who need access, and the building walls you can use.
Tool crib
Woven wire, with a service window or sliding door and a lock matched to the number of users.
General storage or inventory cage
Welded wire.
Schedule III to V controlled substances
The DEA cage, with a ceiling, self-closing self-locking doors and an alarm.
Robot or machine cell
Machine guard fencing set back by the mesh opening, with an interlocked gate.
Equipment that comes out for service
Lift-out panels.
Visitors at the dock
A driver cage.
Stock already on pallet rack
A rack enclosure.
Product can fall from the back of a rack row
Rack safety backing.
Server or network equipment
A server cage.
An opening closed part of the time
A folding or expanding gate.
Many people need access
A keypad or card reader instead of keys.
Section Twelve
Common and costly mistakes
Most come from treating a cage as a commodity.
Short answer: Do not guard machines with 2 in mesh up close, do not buy a latch as a lock, and do not trust a drywall side.
Putting 2 in mesh close to a machine
An arm reaches through it. Allow about 33-1/2 in or use finer mesh.
Comparing quotes on gauge
Ask for mesh, frame and construction.
Hardware reachable from outside
The cage can be unbolted.
Buying a latch as a lock
Two standard options do not lock.
Trusting a drywall side
Verify the building wall or add a panel.
Assuming a cage covers Schedule I and II
Those need a safe or vault.
Forgetting the ceiling
A cage without a top can be climbed.
Choosing the height before checking the sprinklers
Check the clearance on the drawing.
A key lock on a robot cell
The gate needs an interlock.
No way out for people inside
Add exit hardware.
Section Thirteen
Frequently asked questions
What comes up most often on quote calls.
What is the difference between woven and welded wire partitions?
Woven wire is interlaced and welded into a heavy angle frame, so one cut does not open a hole. Welded wire is fused at each crossing into a rigid sheet and is lighter and faster to assemble. WireCrafters lists both in 10 gauge: woven in a 2 in by 1 in mesh and welded in a 2 in by 2 in mesh.
Can I use 2 in wire mesh as a machine guard?
Yes, if the fence stands far enough back. A hand and forearm pass through 2 in openings, and ISO 13857 calls for about 33-1/2 in between a guard with openings that size and the hazard. For a closer fence, use a finer mesh.
What does the DEA require for a controlled substance cage?
For Schedule III, IV and V, 21 CFR 1301.72(b) calls for steel fabric of at least No. 10 gauge on steel posts no more than 10 ft apart, mesh openings no larger than 2-1/2 in, horizontal reinforcements every 60 in, a mesh ceiling or walls attached to the structural ceiling, a steel fabric door and an alarm.
Can Schedule II drugs be stored in a wire cage?
No. Schedule I and II controlled substances call for a safe or vault under 21 CFR 1301.72(a).
How tall are wire partitions?
WireCrafters Style 840 partitions are listed at 8 ft 5-1/4 in, 10 ft 5-1/4 in and 12 ft 5-1/4 in, with panel widths from 1 ft to 10 ft.
How many walls do I need?
Only the sides the building does not provide. A 12 ft by 20 ft crib needs 64 ft of partition free standing, 44 ft against one wall and 32 ft in a corner.
Do all the locks actually lock?
No. The thumb-turn latch and the door knob entry set are listed as latches only. For security, choose a key lock, keypad, coded lock or card reader.
What is a driver cage?
A small wire enclosure at a dock or entry door where drivers and vendors check in and wait, away from fork truck lanes and inventory.
Do I need a ceiling on a security cage?
If someone could climb over the walls, yes. The DEA rule calls for a mesh ceiling or walls attached to the structural ceiling.
How much clearance do sprinklers need above a cage?
NFPA 13 generally calls for at least 18 in between the sprinkler deflector and the top of an obstruction. Have your fire protection contractor confirm it for your building.
What is rack safety backing?
Wire mesh panels on the back of a pallet rack row that keep product from being pushed through into the area behind.
Section Fourteen
Quick-reference tables
Published figures referenced in this guide.
WireCrafters Style 840 as listed
| Item |
Listed |
| Woven wire |
10 gauge, 2 in by 1 in mesh, in a hot-rolled angle frame |
| Welded wire |
10 gauge, 2 in by 2 in mesh, on a 1-1/4 in by 1-1/4 in by 1/8 in angle frame |
| Posts |
2 in square, 14 gauge steel tube |
| Hardware |
3/8 in, reachable from inside only |
| Heights |
8 ft 5-1/4 in, 10 ft 5-1/4 in, 12 ft 5-1/4 in |
| Panel widths |
1 ft to 10 ft in 1 ft steps |
| Ceilings |
Clear spans up to 30 ft |
Before you order
Send a sketch with dimensions, the building walls you plan to use, the ceiling and sprinkler heights, the door locations and how many people need access. Tell us whether the job is security, safety or controlled substances.
About the author. Tom McGovern has worked in the industrial material handling industry since 1981, bringing over 45 years of hands-on experience helping businesses select the right equipment for their applications. His expertise includes specifying and quoting WireCrafters wire partitions, DEA cages, machine guard fencing, driver cages and rack enclosures.