Section One
One system, two meshes
Getting the names straight, because they are used loosely.
Quick answers
- Style 840 is the partition system: posts, panel frames, doors and hardware. It comes with two meshes.
- Woven wire is 10 gauge in a 2 in by 1 in opening, heavy duty. RapidWire welded wire is 10 gauge in a 2 in by 2 in opening, medium duty.
- Choose woven where someone has a reason to get through. Choose welded to separate areas and control traffic.
- Stock heights are 8 ft 5-1/4 in, 10 ft 5-1/4 in and 12 ft 5-1/4 in. Panels are 1 ft to 10 ft wide. Posts go no more than 10 ft 2 in apart.
- Two of the latch sets do not lock, ceiling panels are not load bearing, and anyone working inside needs an exit that needs no key.
Heavy duty
Style 840 woven wire
10 gauge wire in a 2 in by 1 in rectangular opening, interlocked at every crossing. The frame is 1-1/4 in by 1-1/4 in by 1/8 in hot-rolled angle, and panels longer than 3 ft 6 in have flat steel stiffeners welded behind the mesh. See Style 840 woven wire partitions.
Medium duty
RapidWire welded wire
10 gauge wire in a 2 in by 2 in square mesh, welded at each crossing. WireCrafters positions it as the quick ship, fast installation line. See RapidWire welded wire cages.
Confirm the mesh by its size, not its name
The RapidWire name is sometimes used loosely. On a quote, 2 in by 1 in is the woven heavy duty mesh and 2 in by 2 in is the welded medium duty mesh.
This is the product line guide: how to read the part numbers and specify a system. For reach distances, DEA rules and the wider category, see our wire partitions and security cages guide.
Please read this part
This guide is educational and reflects the opinion and general experience of CustomMHS as an equipment distributor. It is not a security, safety or code assessment. Sizes, weights and part numbers are WireCrafters' published figures. Confirm the current data sheet for your exact model before you order.
Section Two
Woven or welded
The first decision. Most of the rest follows from it.
Short answer: Woven resists cutting and reaching through. Welded is a quarter to a third lighter and holds its shape when you cut openings.
Published differences
| Factor |
Woven, 2 in by 1 in |
Welded, 2 in by 2 in |
| Cutting |
Interlocked at every crossing. One cut strand does not open a hole |
Fused at each crossing. Cutting frees the cut wires |
| Reaching through |
The 1 in dimension is listed as stopping a hand |
The 2 in by 2 in opening admits a hand |
| Weight, 8 ft by 4 ft panel |
53 lb |
38 lb |
| Weight, 8 ft by 5 ft panel |
63 lb |
44 lb |
| Cutting openings |
Ask us |
Cutouts can be made and the mesh keeps its shape |
| Duty |
Heavy |
Medium |
| Typical use |
Theft prevention, controlled substances, high-value stock |
Separation and traffic control |
Someone might cut in
Woven.
Someone might reach through
Woven.
Controlled substances
Woven. The DEA cage uses the 2 in by 1 in mesh.
Keeping traffic out of an area
Welded is enough.
Openings for conveyor or ductwork
Welded.
A large run where lifting panels is the hard part
Welded, for the lighter panels.
Do not assume welded is always the lower price or the shorter lead time. Ask for both on your layout and compare.
Section Three
Reading a model number
WireCrafters does not publish a key. This is our reading, checked against the listed dimensions.
Short answer: A cage number gives the mesh, footprint, height, number of walls and door type.
W581H is a woven one-wall cage 5 ft 6 in wide and 8 ft 5-1/4 in high with a hinged door. RW581H is the same cage in welded mesh. RW161484H is a welded four-wall cage on a 16 ft by 14 ft footprint. Use this to compare quotes, and confirm the dimensions on the listing.
Component part numbers
| Component |
Scheme |
Example |
| Woven panels |
Width in feet, then height in feet |
84 is 8 ft by 4 ft |
| Welded panels |
BACK, then width and height |
BACK84 is 8 ft by 4 ft |
| Posts |
RP run or CP corner, then system height in feet |
RP8, CP12 |
| Hinged doors |
HD, width, opening height, system height |
HD-47-10 |
| Double hinged doors |
DHD, same pattern |
DHD-67-8 |
| Sliding doors |
SD, same pattern |
SD-58-8 |
| Rack enclosures |
RE, then width, height and depth |
RE9836 |
| Driver cages |
MT, walls, size, HD |
MT2-56HD |
The same door may appear with or without hyphens, HD-37-8 or HD378. It is the same part.
Section Four
Panels and sizes
Stock sizes, weights, and the filler panel that saves the installation.
Short answer: Panels are 1 ft to 10 ft wide and 4 ft or 5 ft high, and stack to make the system height. Order the adjustable filler panel with the run.
Panels install between posts. Stock widths run from 1 ft to 10 ft in 1 ft steps, in 4 ft and 5 ft heights that stack to the system height.
Listed panel weights
| Panel size |
Woven part |
Woven weight |
Welded part |
Welded weight |
| 1 ft by 4 ft |
14 |
13 lb |
BACK14 |
8 lb |
| 2 ft by 4 ft |
24 |
18 lb |
BACK24 |
12 lb |
| 4 ft by 4 ft |
44 |
31 lb |
BACK44 |
22 lb |
| 6 ft by 4 ft |
64 |
41 lb |
BACK64 |
30 lb |
| 8 ft by 4 ft |
84 |
53 lb |
BACK84 |
38 lb |
| 10 ft by 4 ft |
104 |
63 lb |
BACK104 |
45 lb |
| 8 ft by 5 ft |
85 |
63 lb |
BACK85 |
44 lb |
| 10 ft by 5 ft |
105 |
74 lb |
BACK105 |
54 lb |
The adjustable filler panel
Buildings are not even multiples of one foot. The adjustable filler panel closes the gap at the end of a run. AP4 is for 4 ft high panels and AP5 for 5 ft. They are sheet metal and adjust from 1 in to 11 in.
Finish
The standard finish is gray enamel for interior use. In-stock colors are white, blue, safety yellow, orange, tan, red and black, and custom powder coat is available at added cost. If the partition will see weather, tell us at quote time.
Section Five
Posts, base plates and anchoring
The part that makes a partition a barrier.
Short answer: Posts are 2 in square tube on a welded base plate, anchored with 3/8 in wedge anchors, no more than 10 ft 2 in apart.
Listed post and anchoring details
| Item |
Listed |
| Post |
2 in by 2 in, 14 gauge square tubing |
| Base plate |
1/4 in by 2 in by 7 in plate welded to the post |
| Maximum post spacing |
10 ft 2 in on center |
| Floor anchors |
3/8 in wedge anchors |
| Assembly hardware |
3/8 in plated |
| Floor sweep on stock doors |
3-1/4 in, or 1-3/4 in with a lower cover bar |
| Stock post heights |
8 ft 5-1/4 in, 10 ft 5-1/4 in, 12 ft 5-1/4 in |
| Post part numbers |
RP8, RP10, RP12 run posts. CP8, CP10, CP12 corner posts |
Hardware faces in
The 3/8 in hardware is specified so it cannot be reached from outside the enclosure. The cage has an inside and an outside, and it has to be assembled with the fasteners facing in. Assembled backward, anyone with a nut driver can take it apart.
The whole system bolts together. Nothing is welded on site. On DEA work, post spacing is no more than 10 ft, with horizontal reinforcement.
Section Six
Heights, ceilings and the gap at the top
Whether to close the top is a security decision.
Short answer: Pick the height from the threat. Add ceiling panels or go full height where someone could climb over. Ceiling panels are not load bearing.
Three stock heights are listed: 8 ft 5-1/4 in, 10 ft 5-1/4 in and 12 ft 5-1/4 in. Taller custom heights are available for runs to the roof deck. Ask us.
Worked example. An 8 ft 5-1/4 in partition in a building with 24 ft of clear height leaves 24 ft − 8 ft 5-1/4 in = 15 ft 6-3/4 in of open air above it. Anyone willing to climb a rack or a ladder is inside.
Staffed area, casual deterrence
8 ft 5-1/4 in is normally enough.
Racking or a mezzanine next to the partition
Go taller or add a ceiling. A rack beside a partition is a ladder.
High-value or controlled stock
Ceiling panels, or run to the structural deck.
Unstaffed overnight
A ceiling or full height.
Ceiling panels are an option. They are interchangeable with wall panels, attach with slotted angle, and are listed with clear spans up to 30 ft.
Ceiling panels are not load bearing
A wire ceiling keeps a person from climbing in. It is not a platform or a storage shelf, and nothing should hang from it.
Open mesh lets the building's lighting, ventilation and sprinklers keep working, which is an advantage over a drywall room. Sprinkler coverage over and inside an enclosure is still a question for your fire protection engineer, especially with ceiling panels.
Section Seven
Doors
The door type is usually decided by the clearance you do not have.
Short answer: Hinged doors need swing room. Sliding doors need a clear run of partition beside the opening at least as wide as the door.
Hinged doors are listed 3 ft or 4 ft wide with a 7 ft 3-1/4 in high opening, on two door posts with three hinges. They are universal: left or right hand and in or out swing are set at installation.
Single hinged doors as listed
| Part |
Opening |
Overall height |
Weight |
| HD-37-8 |
3 ft by 7 ft 3-1/4 in |
8 ft 5-1/4 in |
106 lb |
| HD-47-8 |
4 ft by 7 ft 3-1/4 in |
8 ft 5-1/4 in |
118 lb |
| HD-37-10 |
3 ft by 7 ft 3-1/4 in |
10 ft 5-1/4 in |
123 lb |
| HD-47-10 |
4 ft by 7 ft 3-1/4 in |
10 ft 5-1/4 in |
139 lb |
| HD-37-12 |
3 ft by 7 ft 3-1/4 in |
12 ft 5-1/4 in |
138 lb |
| HD-47-12 |
4 ft by 7 ft 3-1/4 in |
12 ft 5-1/4 in |
157 lb |
Double hinged doors give a 6 ft or 8 ft opening at the same height, from DHD-67-8 at 170 lb to DHD-87-12 at 251 lb. Use one where a pallet has to pass and a sliding door will not fit.
Sliding doors, 8 ft system, as listed
| Part |
Opening width |
Weight |
| SD-38-8 |
3 ft |
124 lb |
| SD-48-8 |
4 ft |
137 lb |
| SD-58-8 |
5 ft |
149 lb |
| SD-68-8 |
6 ft |
196 lb |
| SD-88-8 |
8 ft |
230 lb |
| SD-108-8 |
10 ft |
279 lb |
Worked example. A 6 ft sliding door needs 6 ft of opening plus at least 6 ft of clear partition beside it to slide onto. That is 12 ft of wall with nothing stacked against it.
- Dutch doors: two leaves, with an 18 in deep shelf on the bottom leaf. The pass-through counter for a tool crib or driver cage.
- Vertical rise and tunnel doors: made to order for conveyor and vehicle openings.
- Self-closing: a door closer is an option. If your application requires self-closing, self-locking doors, put it in writing on the order.
Section Eight
Locks, latches and exit devices
The lock is a separate line from the door.
Short answer: SF2-SB1 and SF3-SB3 latch but do not lock. Where a door locks and people work inside, add an exit device.
Listed locking options
| Part |
Description |
Fits |
| SF-1 / SB-1 |
Key lock outside, recessed thumb turn inside |
Hinged |
| SDLKXKD |
Key lock and thumb turn for a sliding door |
Sliding |
| SF2-SB1 |
Thumb turn latch. Latches only, does not lock |
Hinged or sliding |
| SF3-SB3 |
Door knob entry. Latches only, does not lock |
Hinged |
| SF1-SB4 |
Key lock with lever handle inside. Listed as meeting ADA requirements |
Hinged |
| CF1-CB1 |
ADA handle set |
Hinged |
| CE-2 |
Ten-digit keypad for an electric strike or magnetic lock, up to 64 codes |
Either |
| CF-2 |
Five-button coded lock |
Hinged |
| CE-3 |
Magnetic lock |
Sliding |
| Card reader |
Works an electric strike or magnetic lock, with ten cards |
Either |
Exit devices: CB-2 is a push paddle, CB-3 is a push bar across the full width of the door, and CD-4 is a push bar with a battery-powered alarm. See WireCrafters locks.
People inside need a way out
If anyone works inside the enclosure, they have to be able to leave without a key. That is a building code matter, so confirm it with your building official. On a multi-cage project, price the locking hardware early. It can be a large part of the job.
Section Nine
One, two, three and four wall cages
Buy only the walls you do not already have.
Short answer: Count the solid, full-height building walls you can use. Everything else is partition.
Wall configurations
| Cage |
Where it goes |
| 1 wall |
Between two existing walls, closing an alcove |
| 2 wall |
In a building corner |
| 3 wall |
Against one building wall. The most common |
| 4 wall |
Free standing on open floor, with or without a ceiling |
Check what the existing wall is
A stud and drywall wall is not as secure as the partition, and neither is a wall that stops at a drop ceiling with open space above. Walk the perimeter before you decide how many walls to buy.
Listed applications include tool cribs, server cages, evidence enclosures, driver cages and DEA drug storage. Tenant storage lockers are a related line covered in our lockers guide.
Section Ten
Rack enclosures and rack backing
Two products that bolt to pallet rack and solve two different problems.
Short answer: Rack backing keeps product from falling into the aisle behind. A rack enclosure turns bays into locked storage.
Rack backing
Rack safety backing uses the welded BACK panels, up to 12 ft wide and 4 ft or 5 ft high, mounted to the back of the rack. It is a falling-object control.
Rack enclosures
Pallet rack enclosures, the RE series, add wire sides, backs and doors to rack bays for secured storage. Part numbers give width, height and depth.
Neither changes the capacity or condition of the rack. Our pallet racking guide covers rack inspection.
Section Eleven
DEA cages
Where the federal rule sets the specification.
Short answer: For Schedule III to V storage, use the woven 2 in by 1 in mesh, posts no more than 10 ft apart, horizontal bars every 5 ft, a ceiling, and self-closing, self-locking doors.
21 CFR 1301.72(b) sets the construction of a controlled substance cage: steel fabric of at least No. 10 gauge, mesh openings no larger than 2-1/2 in, posts no more than 10 ft apart, horizontal reinforcements every 60 in, a mesh ceiling or walls attached to the structural ceiling, and an alarm. The WireCrafters DEA cage is built to those numbers with the woven mesh. Schedule I and II substances need a safe or vault.
Our wire partitions guide sets out the rule in a table. Confirm your requirements with the DEA and your compliance counsel before you order.
Section Twelve
Machine guarding
Use the product made for it.
Short answer: A security partition is not automatically a machine guard. Guard fencing is laid out from the hazard, the mesh opening and a risk assessment.
Around a machine or robot, the fence has to keep a person from reaching the hazard. That depends on the mesh opening and the distance, under ISO 13857, and the gate normally needs an interlock tied to the machine. WireCrafters makes machine guard fencing and lift-out RapidGuard fencing for that job.
Our barriers and machine guarding guide and wire partitions guide cover reach distances. Have the layout confirmed by your safety engineer.
Section Thirteen
Laying out a run
A planning example. We do the final layout from your sketch.
Short answer: Add the panel widths and 2 in for each post, compare to the wall, and close the remainder with a filler panel.
A single wall closing an alcove that measures 23 ft 7 in, which is 283 in, with no door:
Planning a 23 ft 7 in run
| Step |
Math |
Result |
| Panels |
10 ft + 10 ft + 2 ft |
22 ft, or 264 in |
| Posts |
4 posts × 2 in |
8 in |
| Panels and posts |
264 in + 8 in |
272 in |
| Left over |
283 in − 272 in |
11 in |
| Close the gap |
Adjustable filler, 1 in to 11 in |
One filler panel stack |
For the 8 ft 5-1/4 in system that run is two rows of 4 ft high panels, so six panels and two AP4 fillers. Send us the wall dimensions, the door locations and anything that crosses the line, such as pipes, conduit or a conveyor.
Section Fourteen
Common and costly mistakes
Most show up on installation day.
Short answer: Order the filler, face the hardware in, check the parking wall for a sliding door, and do not buy a latch as a lock.
Choosing by the line name
Confirm 2 in by 1 in woven or 2 in by 2 in welded.
Forgetting the filler panel
A partition that stops 7 in short of a wall is not secure.
Assembling with the hardware facing out
The fasteners belong inside.
Posts more than 10 ft 2 in apart
That is outside the listed maximum.
Stopping at 8 ft beside a rack
A rack is a ladder.
Storing on the ceiling panels
They are not load bearing.
A sliding door with no room to slide
It needs clear partition beside the opening.
A latch where a lock was needed
SF2-SB1 and SF3-SB3 do not lock.
No exit device
People inside need to get out without a key.
A security partition as a machine guard
Use guard fencing laid out from a risk assessment.
Section Fifteen
Frequently asked questions
What buyers ask when specifying Style 840.
What is WireCrafters Style 840?
It is a wire partition system of posts, framed panels, doors and hardware. It comes with woven wire in a 2 in by 1 in mesh or RapidWire welded wire in a 2 in by 2 in mesh, both 10 gauge.
What is the difference between Style 840 woven wire and RapidWire?
Woven wire is interlocked at every crossing in a 2 in by 1 in opening and is the heavy duty choice for security. RapidWire is welded in a 2 in by 2 in opening, is lighter, and suits separation and traffic control.
How do I read a WireCrafters cage model number?
W or RW is the mesh, the next digits are the footprint, then the height class, the number of walls and the door type. W664H reads as woven, 6 ft 6 in by 6 ft 4 in, four walls, hinged door, with the height digit between.
What heights does Style 840 come in?
Stock system heights are 8 ft 5-1/4 in, 10 ft 5-1/4 in and 12 ft 5-1/4 in. Taller custom heights are available.
What panel sizes are stocked?
Widths from 1 ft to 10 ft in 1 ft steps, in 4 ft and 5 ft heights that stack to the system height.
How far apart can the posts be?
The listed maximum is 10 ft 2 in on center. On DEA cages it is no more than 10 ft.
How much does a panel weigh?
An 8 ft by 4 ft woven panel is listed at 53 lb and the welded panel at 38 lb.
Can I put anything on the ceiling panels?
No. Ceiling panels are not load bearing. They close the top of the cage against climbing.
Hinged or sliding door?
A hinged door needs swing room. A sliding door needs a clear run of partition beside the opening at least as wide as the door.
Do the latch sets lock?
SF2-SB1 and SF3-SB3 are listed as latches only. For a locking door choose a key lock, keypad, coded lock or card reader, and add an exit device if people work inside.
Is Style 840 used for DEA cages?
Yes. The WireCrafters DEA cage uses the woven 2 in by 1 in mesh with posts no more than 10 ft apart, horizontal bars every 5 ft, a ceiling, and self-closing, self-locking doors.
Section Sixteen
Quick-reference tables
The system on one screen.
Style 840 at a glance
| Item |
Listed |
| Woven mesh |
10 gauge, 2 in by 1 in |
| Welded mesh |
10 gauge, 2 in by 2 in |
| Panel widths |
1 ft to 10 ft |
| Panel heights |
4 ft and 5 ft |
| System heights |
8 ft 5-1/4 in, 10 ft 5-1/4 in, 12 ft 5-1/4 in |
| Posts |
2 in by 2 in, 14 gauge, 10 ft 2 in maximum spacing |
| Anchors and hardware |
3/8 in |
| Filler panel |
Adjusts 1 in to 11 in |
| Hinged door opening |
3 ft or 4 ft by 7 ft 3-1/4 in |
| Ceiling clear span |
Up to 30 ft |
Before you order
Send a sketch with dimensions, door locations and swings, ceiling height, what the building walls are made of, and who needs access.
About the author. Tom McGovern has worked in the industrial material handling industry since 1981, bringing over 45 years of hands-on experience helping businesses select the right equipment for their applications. His expertise includes specifying and quoting WireCrafters Style 840 woven wire, RapidWire welded wire, DEA cages and rack enclosures.
Questions about this guide? Call 866-333-0728 to speak with an experienced material handling specialist.